SDG100
Compressed air meter. SDG4"/METRIS PB DN100
Precise measurement of flow and consumption. High accuracy, repeatability and measurement dynamics. For detecting compressed air in industrial use. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | flange DN100 according to: DIN 2448 |
Application: | totaliser function |
Media: | compressed air |
Note on media: | air quality ISO 8573-1 class 141 class 344 |
Medium temperature [°C]: | 0...60 |
Pressure rating [bar]: | 16 |
Pressure rating [Mpa]: | 1.6 |
Operating voltage [V]: | 19...30 DC |
Current consumption [mA]: | < 100 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.5 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; pulse signal; (configurable) |
Electrical design: | PNP |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250; (per output) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Pulse output: | consumed quantity meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range [m³/h]: | 15...4400 |
Display range [m³/h]: | 0...5320 |
Pulse value: | 10 Nm³ |
Pulse length [s]: | 0,1 |
Accuracy (in the measuring range): | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344) |
Response time [s]: | 0.1; (dAP = 0) |
Ambient temperature [°C]: | 0...60 |
Storage temperature [°C]: | -20...85 |
Max. relative air humidity [%]: | 90 |
Protection: | IP 65 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Vibration resistance: | DIN IEC 68-2-6 5 g (55...2000 Hz) |
DIN IEC 68-2-6: | 5 g (55...2000 Hz) |
MTTF [years]: | 214 |
Weight [g]: | 13873 |
Materials: | PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM; pipe section: steel galvanised |
Materials (wetted parts): | stainless steel (1.4401 / 316); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised; steel galvanised |
Process connection: | flange DN100 according to: DIN 2448 |
Remarks: | MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. For information about installation and operation please see the operating instructions. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 13.87 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |