Ifm SDG082

Compressed air meter. SDG3"/METRIS PB DN80 LM

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow and consumption. High accuracy, repeatability and measurement dynamics. For detecting compressed air in industrial use. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: flange DN80 according to: DIN 2448
Application: totaliser function
Media: compressed air
Note on media: air quality ISO 8573-1 class 141 class 344
Medium temperature [°C]: 0...60
Pressure rating [bar]: 16
Pressure rating [Mpa]: 1.6
Operating voltage [V]: 19...30 DC
Current consumption [mA]: < 100
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 0.5
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range [m³/h]: 9...2750
Display range [m³/h]: 0...3300
Pulse value: 1 Nm³
Pulse length [s]: 0,1
Accuracy (in the measuring range): ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344)
Response time [s]: 0.1; (dAP = 0)
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -20...85
Max. relative air humidity [%]: 90
Protection: IP 65
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Vibration resistance: DIN IEC 68-2-6 5 g (55...2000 Hz)
DIN IEC 68-2-6: 5 g (55...2000 Hz)
MTTF [years]: 214
Weight [g]: 12600
Materials: PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM; pipe section: steel galvanised
Materials (wetted parts): stainless steel (1.4401 / 316); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised; pipe section: steel galvanised
Process connection: flange DN80 according to: DIN 2448
Remarks: MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. For information about installation and operation please see the operating instructions.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 12.60 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m