Ifm SD8000

Compressed air meter. SDR11DGXFPKG/US-100

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting compressed air in industrial use. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection R 1 DN25
Measuring range [°C]: 0...60
Application: for industrial applications
Media: compressed air
Note on media: air quality ISO 8573-1 class 141 class 344
Medium temperature [°C]: 0...60
Pressure rating [bar]: 16
Pressure rating [Mpa]: 1.6
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 110
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 1
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: 13...3750 l/min 0.4...109.2 m/s 0.7...225 m³/h
13...3750 l/min: 0.4...109.2 m/s
Display range: 0...4500 l/min 0...131 m/s 0...270 m³/h
0...4500 l/min: 0...131 m/s
Set point SP: 30...3750 l/min 0.9...109.2 m/s 1.8...225 m³/h
30...3750 l/min: 0.9...109.2 m/s
Reset point rP: 12...3732 l/min 0.4...108.7 m/s 0.7...223.9 m³/h
12...3732 l/min: 0.4...108.7 m/s
Analogue start point ASP: 0...2813 l/min 0...81.9 m/s 0...168.8 m³/h
0...2813 l/min: 0...81.9 m/s
Analogue end point AEP: 937...3750 l/min 27.3...109.2 m/s 56.2...225 m³/h
937...3750 l/min: 27.3...109.2 m/s
In steps of: 1 l/min 0.1 m/s 0.1 m³/h
1 l/min: 0.1 m/s
Pulse value: 0.003...3000000 m³
In steps of: 0.001 m³
Pulse length [s]: 0,02...2
Measuring range [°C]: 0...60
Display range [°C]: -12...72
Repeatability [% of the measured value]: ± 1,5
Accuracy (in the measuring range): ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN25)
Accuracy [K]: ± 2; (medium flow in the limit area of the flow measurement range)
Response time [s]: 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s]: 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Parameter setting options: Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 267 d / 00 01 0B h
Profiles: no profile
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 4.1
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -20...85
Max. relative air humidity [%]: 90
Protection: IP 65
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Vibration resistance: DIN EN 68000-2-6 5 g (55...2000 Hz)
DIN EN 68000-2-6: 5 g (55...2000 Hz)
MTTF [years]: 227
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 2065.2
Materials: PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts): stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium
Process connection: threaded connection R 1 DN25
Display: Display unit 5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C) function display 1 x LED, green switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C)
function display: 1 x LED, green
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Remarks: MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. For information about installation and operation please see the operating instructions.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 2.07 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m