Ifm SD6101

Flow rate meter for gases. SDN12DGXFPKG/US-100

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2). With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection 1/2" NPT DN15
Measuring range [°F]: 32...140
Application: for industrial applications
Media: Argon (Ar); carbon dioxide (CO2); nitrogen (N2)
Medium temperature [°F]: 32...140
Pressure rating [bar]: 16
Pressure rating [psi]: 232
MAWP (for applications according to CRN) [bar]: 16
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 100
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 1
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Low flow cut-off LFC: < 46 scfh < 0.76 scfm 1...5.8 sfs
< 46 scfh: < 0.76 scfm
Measuring dynamics: 1:300
Measuring range: 15...4310 scfh 0.2...71.8 scfm 2...552 sfs
15...4310 scfh: 0.2...71.8 scfm
Display range: 0...5170 scfh 0...86.2 scfm 0...663 sfs
0...5170 scfh: 0...86.2 scfm
Resolution: 5 scfh 0.1 scfm 1 sfs
5 scfh: 0.1 scfm
Set point SP: 40...4310 scfh 0.7...71.8 scfm 5...552 sfs
40...4310 scfh: 0.7...71.8 scfm
Reset point rP: 20...4290 scfh 0.4...71.5 scfm 3...550 sfs
20...4290 scfh: 0.4...71.5 scfm
Analogue start point ASP: 0...3445 scfh 0...57.4 scfm 0...442 sfs
0...3445 scfh: 0...57.4 scfm
Analogue end point AEP: 860...4310 scfh 14.4...71.8 scfm 110...552 sfs
860...4310 scfh: 14.4...71.8 scfm
In steps of: 5 scfh 0.1 scfm 1 sfs
5 scfh: 0.1 scfm
Measuring range: 10...2640 scfh 0.15...44 scfm 1...338.5 sfs
10...2640 scfh: 0.15...44 scfm
Display range: 0...3170 scfh 0...52.8 scfm 0...406 sfs
0...3170 scfh: 0...52.8 scfm
Resolution: 5 scfh 0.05 scfm 0.5 sfs
5 scfh: 0.05 scfm
Set point SP: 25...2640 scfh 0.4...44 scfm 3...338.5 sfs
25...2640 scfh: 0.4...44 scfm
Reset point rP: 15...2630 scfh 0.2...43.8 scfm 1.5...337 sfs
15...2630 scfh: 0.2...43.8 scfm
Analogue start point ASP: 0...2110 scfh 0...35.2 scfm 0...271 sfs
0...2110 scfh: 0...35.2 scfm
Analogue end point AEP: 530...2640 scfh 8.8...44 scfm 67.5...338.5 sfs
530...2640 scfh: 8.8...44 scfm
In steps of: 5 scfh 0.05 scfm 0.5 sfs
5 scfh: 0.05 scfm
Pulse value: 0.040...4 000 000 scf
In steps of: 0.020...1000 scf
Pulse length [s]: 0,007...2
Measuring range: 10...2650 scfh 0.15...44.15 scfm 1...339.5 sfs
10...2650 scfh: 0.15...44.15 scfm
Display range: 0...3175 scfh 0...52.95 scfm 0...407.5 sfs
0...3175 scfh: 0...52.95 scfm
Resolution: 5 scfh 0.05 scfm 0.5 sfs
5 scfh: 0.05 scfm
Set point SP: 25...2650 scfh 0.4...44.15 scfm 3...339.5 sfs
25...2650 scfh: 0.4...44.15 scfm
Reset point rP: 15...2635 scfh 0.2...43.95 scfm 1.5...338 sfs
15...2635 scfh: 0.2...43.95 scfm
Analogue start point ASP: 0...2120 scfh 0...35.3 scfm 0...271.5 sfs
0...2120 scfh: 0...35.3 scfm
Analogue end point AEP: 530...2650 scfh 8.85...44.15 scfm 68...339.5 sfs
530...2650 scfh: 8.85...44.15 scfm
In steps of: 5 scfh 0.05 scfm 0.5 sfs
5 scfh: 0.05 scfm
Measuring range [°F]: 32...140
Display range [°F]: 10.5...161.5
Resolution [°F]: 0.5
Set point SP [°F]: 32.5...140
Reset point rP [°F]: 32...139.5
Analogue start point [°F]: 32...118.5
Analogue end point [°F]: 53.5...140
In steps of [°F]: 0.5
Repeatability [% of the measured value]: ± 1,5
Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15)
Accuracy [K]: ± 2; (medium flow in the limit area of the flow measurement range)
Response time [s]: 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s]: 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Parameter setting options: Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 266 d / 00 01 0a h
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 4.1
Ambient temperature [°F]: 32...140
Storage temperature [°F]: -4...185
Max. relative air humidity [%]: 90
Protection: IP 65
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Vibration resistance: DIN IEC 68-2-6 5 g (55...2000 Hz)
DIN IEC 68-2-6: 5 g (55...2000 Hz)
MTTF [years]: 227
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 925.5
Materials: PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts): stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised
Process connection: threaded connection 1/2" NPT DN15
Display: Display unit 4 x LED, green (scfm, scfh, scf, °F) function display 1 x LED, yellow switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 4 x LED, green (scfm, scfh, scf, °F)
function display: 1 x LED, yellow
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Display unit: scfm; scfh; scf; °F
Remarks: MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.93 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m