Ifm SD6100

Flow rate meter for gases. SDR12DGXFPKG/US-100

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2). With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection R 1/2 DN15
Measuring range [°C]: 0...60
Application: for industrial applications
Media: Argon (Ar); carbon dioxide (CO2); nitrogen (N2)
Medium temperature [°C]: 0...60
Pressure rating [bar]: 16
Pressure rating [Mpa]: 1.6
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 100
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 1
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Low flow cut-off LFC [m³/h]: < 1.3
Measuring dynamics: 1:300
Measuring range [m³/h]: 0.4...122
Display range [m³/h]: 0...146.4
Resolution [m³/h]: 0.1
Set point SP [m³/h]: 1.1...122
Reset point rP [m³/h]: 0.6...121.5
Analogue start point ASP [m³/h]: 0...97.6
Analogue end point AEP [m³/h]: 24.4...122
In steps of [m³/h]: 0.1
Measuring range [m³/h]: 0.2...74.7
Display range [m³/h]: 0...89.7
Resolution [m³/h]: 0.1
Set point SP [m³/h]: 0.7...74.7
Reset point rP [m³/h]: 0.4...74.4
Analogue start point ASP [m³/h]: 0...59.8
Analogue end point AEP [m³/h]: 14.9...74.7
In steps of [m³/h]: 0.1
Pulse value: 0.001...1 000 000 m³
In steps of: 0.001...1000 m³
Pulse length [s]: 0,012...2
Measuring range [m³/h]: 0.2...75
Display range [m³/h]: 0...90
Resolution [m³/h]: 0.1
Set point SP [m³/h]: 0.7...75
Reset point rP [m³/h]: 0.4...74.7
Analogue start point ASP [m³/h]: 0...60
Analogue end point AEP [m³/h]: 15...75
In steps of [m³/h]: 0.1
Measuring range [°C]: 0...60
Display range [°C]: -12...72
Resolution [°C]: 0.2
Set point SP [°C]: 0.4...60
Reset point rP [°C]: 0...59.8
Analogue start point [°C]: 0...48
Analogue end point [°C]: 12...60
In steps of [°C]: 0.2
Repeatability [% of the measured value]: ± 1,5
Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15)
Accuracy [K]: ± 2; (medium flow in the limit area of the flow measurement range)
Response time [s]: 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s]: 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Parameter setting options: Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 265 d / 00 01 09 h
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 4.1
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -20...85
Max. relative air humidity [%]: 90
Protection: IP 65
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Vibration resistance: DIN IEC 68-2-6 5 g (55...2000 Hz)
DIN IEC 68-2-6: 5 g (55...2000 Hz)
MTTF [years]: 227
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 963.5
Materials: PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts): stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised
Tightening torque [Nm]: 50
Process connection: threaded connection R 1/2 DN15
Display: Display unit 4 x LED, green (Nl/min, Nm³/h, Nm³, °C) function display 1 x LED, yellow switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 4 x LED, green (Nl/min, Nm³/h, Nm³, °C)
function display: 1 x LED, yellow
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Display unit: Nl/min; Nm³/h; Nm³; °C
Remarks: MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.96 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m