Ifm SD0523

Compressed air meter. SDD11DGXFPKG/US-100

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting compressed air in industrial use. With switching output, analogue output and pulse output. Adjustable to inside pipe diameters

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection G 1 internal thread
Measuring range [°C]: 0...60
Installation: Adjustable to inside pipe diameters; (38...254 mm)
Media: compressed air
Medium temperature [°C]: 0...60
Pressure rating [bar]: 16
Pressure rating [Mpa]: 1.6
Pressure rating [psi]: 232
MAWP (for applications according to CRN) [bar]: 16
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 110
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 1
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: Measuring/setting range; Flow monitoring; The values apply at: Ø 72 mm
Measuring range: 0.5...143.9 m/s 8...2110 m³/h 0.12...35.18 m³/min
0.5...143.9 m/s: 8...2110 m³/h
Display range: 0...172.7 m/s 0...2532 m³/h 0...42.22 m³/min
0...172.7 m/s: 0...2532 m³/h
Resolution: 0.1 m/s 2 m³/h 0.02 m³/min
0.1 m/s: 2 m³/h
Set point SP: 1.2...143.9 m/s 18...2110 m³/h 0.28...35.18 m³/min
1.2...143.9 m/s: 18...2110 m³/h
Reset point rP: 0.5...143.2 m/s 6...2100 m³/h 0.12...35 m³/min
0.5...143.2 m/s: 6...2100 m³/h
Analogue start point ASP: 0...107.9 m/s 0...1582 m³/h 0...26.38 m³/min
0...107.9 m/s: 0...1582 m³/h
Analogue end point AEP: 36...143.9 m/s 528...2110 m³/h 8.8...35.18 m³/min
36...143.9 m/s: 528...2110 m³/h
In steps of: 0.1 m/s 2 m³/h 0.02 m³/min
0.1 m/s: 2 m³/h
Pulse value: 1...1000 x 10³
In steps of: 1 Nm³
Pulse length [s]: 0,7...2 (D = 72 mm)
Measuring range [°C]: 0...60
Display range [°C]: -12...72
Resolution [°C]: 0.2
Set point SP [°C]: 0.4...60
Reset point rP [°C]: 0.2...59.8
Analogue start point [°C]: 0...45
Analogue end point [°C]: 15...60
In steps of [°C]: 0.2
Repeatability [% of the measured value]: ± 1,5
Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); (D = 72mm, T = 22 °C; standard volume flow: 50...850 Nm³/h)
Accuracy [K]: ± 2,5 (Q > 2 Nm³/h)
Response time [s]: 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s]: 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Dynamic response T05 / T09 [s]: 30 (Q > 2 Nm³/h)
Parameter setting options: Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 381d / 00 01 7D h
Profiles: Smart Sensor: Process Data Variable; Device Identification
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 5
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -20...85
Max. relative air humidity [%]: 90
Protection: IP 65
EMC: DIN EN 60947-5-9 DIN EN 61000-6-3
Vibration resistance: DIN EN 60068-2-6 5 g (55...2000 Hz)
DIN EN 60068-2-6: 5 g (55...2000 Hz)
MTTF [years]: 213
Weight [g]: 442
Materials: PBT-GF20; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts): stainless steel (1.4401 / 316); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM
Process connection: threaded connection G 1 internal thread
Display: Display unit 4 x LED, green (Nm³/min, Nm³/h, Nm³, °C) function display 1 x LED, green switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 4 x LED, green (Nm³/min, Nm³/h, Nm³, °C)
function display: 1 x LED, green
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Remarks: Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. D = inside pipe diameter
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.44 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m