SB2246
Flow meter with integrated backflow prevention and display. SBG11KL0FRKG
| Process connection: | threaded connection G 1 internal thread | 
| Measuring range: | -10...100 °C 14...212 °F | 
| -10...100 °C: | 14...212 °F | 
| Special feature: | Gold-plated contacts | 
| Media: | Liquids; oil | 
| Note on media: | oil with viscosity: 46 mm²/s (40 °C) | 
| Medium temperature [°C]: | -10...100 | 
| Pressure rating [bar]: | 100 | 
| Note on pressure rating: | at medium temperature >70°C: 80 | 
| Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA]: | < 50 | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Power-on delay time [s]: | < 3 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal; analogue signal; frequency signal; IO-Link | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Max. current load per output [mA]: | 150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature) | 
| Analogue current output [mA]: | 4...20 | 
| Max. load [Ω]: | 500 | 
| Short-circuit protection: | yes | 
| Overload protection: | yes | 
| Frequency of the output [Hz]: | 0...10000 | 
| Measuring range: | 2...100 l/min 0.12...6 m³/h 32...1586 gph 0.55...26.4 gpm | 
| 2...100 l/min: | 0.12...6 m³/h | 
| Display range: | 0...120 l/min 0...7.2 m³/h 0...1902 gph 0...31.7 gpm | 
| 0...120 l/min: | 0...7.2 m³/h | 
| Resolution: | 0.1 l/min 0.01 m³/h 1 gph 0.01 gpm | 
| 0.1 l/min: | 0.01 m³/h | 
| Set point SP: | 0.7...100 l/min 0.04...6 m³/h 10...1586 gph 0.15...26.4 gpm | 
| 0.7...100 l/min: | 0.04...6 m³/h | 
| Reset point rP: | 0...99.3 l/min 0...5.96 m³/h 0...1574 gph 0...26.25 gpm | 
| 0...99.3 l/min: | 0...5.96 m³/h | 
| Frequency end point, FEP: | 6.7...100 l/min 0.4...6 m³/h 106...1586 gph 1.75...26.4 gpm | 
| 6.7...100 l/min: | 0.4...6 m³/h | 
| In steps of: | 0.1 l/min 0.01 m³/h 2 gph 0.05 gpm | 
| 0.1 l/min: | 0.01 m³/h | 
| Frequency at the end point FRP [Hz]: | 10...10000 | 
| In steps of [Hz]: | 10 | 
| Measuring dynamics: | 1:50 | 
| In steps of: | 10 Hz | 
| Measuring range: | -10...100 °C 14...212 °F | 
| -10...100 °C: | 14...212 °F | 
| Display range: | -32...122 °C -25.6...251.6 °F | 
| -32...122 °C: | -25.6...251.6 °F | 
| Resolution: | 0.1 °C 0.1 °F | 
| 0.1 °C: | 0.1 °F | 
| Set point SP: | -9.3...100 °C 15.2...212 °F | 
| -9.3...100 °C: | 15.2...212 °F | 
| Reset point rP: | -10...99.3 °C 14...210.8 °F | 
| -10...99.3 °C: | 14...210.8 °F | 
| In steps of: | 0.1 °C 0.2 °F | 
| 0.1 °C: | 0.2 °F | 
| Frequency start point, FSP: | -10...78 °C 14...172.4 °F | 
| -10...78 °C: | 14...172.4 °F | 
| Frequency end point, FEP: | 12...100 °C 53.6...212 °F | 
| 12...100 °C: | 53.6...212 °F | 
| Frequency at the end point FRP [Hz]: | 10...10000 | 
| Accuracy (in the measuring range): | ± 5 % MEW; (Q > 1 l/min; 20...70 °C Medium temperature) | 
| Repeatability: | ± 1 % MEW | 
| Temperature drift: | 0,029 °C / K | 
| Accuracy [K]: | 3 K (25°C; Q > 1 l/min) | 
| Response time [s]: | 0.01 | 
| Damping for the switching output dAP [s]: | 0...5 | 
| In steps of [s]: | 0.1 | 
| Damping for the analogue output dAA [s]: | 0...5 | 
| In steps of [s]: | 0.1 | 
| Dynamic response T05 / T09 [s]: | T09 = 120 (Q > 1 l/min) | 
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor | 
| Communication interface: | IO-Link | 
| Transmission type: | COM2 (38,4 kBaud) | 
| IO-Link revision: | 1.1 | 
| SDCI standard: | IEC 61131-9 CDV | 
| IO-Link device ID: | 1046 d / 0416 h | 
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
| SIO mode: | yes | 
| Required master port type: | A | 
| Process data analogue: | 2 | 
| Process data binary: | 2 | 
| Min. process cycle time [ms]: | 3.2 | 
| Ambient temperature [°C]: | 0...60 | 
| Note on ambient temperature: | medium temperature < 80 °C medium temperature < 100 °C: 0...40 °C | 
| Storage temperature [°C]: | -15...80 | 
| Protection: | IP 65; IP 67 | 
| EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 | 
| Shock resistance: | DIN EN 60068-2-27 20 g (11 ms) | 
| DIN EN 60068-2-27: | 20 g (11 ms) | 
| Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) | 
| DIN EN 60068-2-6: | 5 g (10...2000 Hz) | 
| MTTF [years]: | 145 | 
| UL approval: | UL Approval no. I006 | 
| UL Approval no.: | I006 | 
| Pressure Equipment Directive: | Sound engineering practice | 
| Weight [g]: | 1575 | 
| Materials: | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated | 
| Materials (wetted parts): | stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM | 
| Process connection: | threaded connection G 1 internal thread | 
| Switching cycles mechanical: | 10 million | 
| Display: | Display unit 6 x LED, green switching status 2 x LED, yellow measured values alphanumeric display, red/green alternating indication 4-digit programming alphanumeric display, 4-digit | 
| Display unit: | 6 x LED, green | 
| switching status: | 2 x LED, yellow | 
| measured values: | alphanumeric display, red/green alternating indication 4-digit | 
| programming: | alphanumeric display, 4-digit | 
| Remarks: | Recommendation: use a 200-micron filter. All data refer to oil with the following nominal viscosity: 46 mm²/s, 40 °C MW = measured value MEW = Final value of the measuring range | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M12; Contacts: gold-plated | 
| ECCN: | |
| Country of Origin: | DE | 
| EAN: | |
| Weight: | 1.58 kg | 
| Length: | 0.00 m | 
| Width: | 0.00 m | 
| Height: | 0.00 m |