PY9970
Pressure sensor with display. PY-400-SDD24-KFPKG/US/ /N
Suited for use in homogeniser processes. Intuitive, user-friendly handling. Analogue output and switching output for alarm function. Integrated, clearly readable display. With long-term stability thanks to high overload protection
Output signal: | switching signal; analogue signal; (configurable) |
Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa |
0...400 bar: | 0...5800 psi |
Process connection: | homogeniser connection |
Special feature: | Gold-plated contacts |
Application: | food and beverage industry |
Conditionally suitable for: | For gaseous media the application is limited to max. 25 bar. |
Medium temperature [°C]: | -10...140 |
Min. bursting pressure: | 1000 bar 14500 psi 100 MPa |
1000 bar: | 14500 psi |
Pressure rating: | 600 bar 8700 psi 60 Mpa |
600 bar: | 8700 psi |
Type of pressure: | relative pressure |
Operating voltage [V]: | 20...32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 65 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.2 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | < 170 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable 1:4) |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Analogue voltage output [V]: | 0...10; (scalable 1:4) |
Min. load resistance [Ω]: | 2000 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa |
0...400 bar: | 0...5800 psi |
Set point SP: | 4...400 bar 60...5800 psi 0.4...40 MPa |
4...400 bar: | 60...5800 psi |
Reset point rP: | 2...398 bar 30...5770 psi 0.2...39.8 MPa |
2...398 bar: | 30...5770 psi |
Analogue start point: | 0...160 bar 0...2320 psi 0...16 MPa |
0...160 bar: | 0...2320 psi |
Analogue end point: | 100...400 bar 1450...5800 psi 10...40 MPa |
100...400 bar: | 1450...5800 psi |
In steps of: | 1 bar 10 psi 0.1 MPa |
1 bar: | 10 psi |
Factory setting: | SP1 = 100 bar rP1 = 92 bar SP2 = 300 bar rP2 = 292 bar ASP = 0 bar AEP = 400 bar |
Switch point accuracy [% of the span]: | < ± 1,0 |
Repeatability [% of the span]: | < ± 0,25; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 1,0 |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,3; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,3; (0...80 °C) |
Response time [ms]: | < 3 |
Damping for the switching output dAP [s]: | 0...4 |
Damping for the analogue output dAA [s]: | 0...4 |
Max. response time analogue output [ms]: | 3 |
Parameter setting options: | zero point; span |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5/1 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 173.33 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 1588.5 |
Materials: | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM |
Materials (wetted parts): | stainless steel |
Min. pressure cycles: | 1 million |
Process connection: | homogeniser connection |
Display: | Display unit 3 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | 3 x LED, green |
switching status: | 2 x LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 1.59 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |