PY2033
Pressure sensor with display. PN-025-RDR12-MFRKG/US/ /V
Two switching outputs, one of them programmable as analogue output. Clearly visible 4-digit LED display. Country-specific pressure units selectable. With long-term stability thanks to high overload protection. Selectable output polarity
Output signal: | switching signal; analogue signal; (configurable) |
Measuring range: | -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa |
-1...25 bar: | -14.5...362.5 psi |
Process connection: | threaded connection G 1/2 external thread |
Special feature: | Gold-plated contacts |
Media: | liquids and gases |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 200 bar 2900 psi 20 MPa |
200 bar: | 2900 psi |
Pressure rating: | 100 bar 1450 psi 10 Mpa |
100 bar: | 1450 psi |
Type of pressure: | relative pressure |
No dead space: | yes |
Operating voltage [V]: | 18...32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 35 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.3 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | < 500 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable 1:4) |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Analogue voltage output [V]: | 0...10; (scalable 1:4) |
Min. load resistance [Ω]: | 2000 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa |
-1...25 bar: | -14.5...362.5 psi |
Set point SP: | -0.8...25 bar -11.5...362.5 psi -0.08...2.5 MPa |
-0.8...25 bar: | -11.5...362.5 psi |
Reset point rP: | -0.9...24.9 bar -13...361 psi -0.09...2.49 MPa |
-0.9...24.9 bar: | -13...361 psi |
Analogue start point: | -1...18.75 bar -14.5...272 psi -0.1...1.88 MPa |
-1...18.75 bar: | -14.5...272 psi |
Analogue end point: | 5.25...25 bar 76...362.5 psi 0.53...2.5 MPa |
5.25...25 bar: | 76...362.5 psi |
In steps of: | 0.05 bar 0.5 psi 0.01 MPa |
0.05 bar: | 0.5 psi |
Factory setting: | SP1 = 6.25 bar rP1 = 5.75 bar SP2 = 18.75 bar rP2 = 18.25 bar ASP = 0.00 bar AEP = 25.00 bar |
Switch point accuracy [% of the span]: | < ± 0,4; (Turn down 1:1) |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,3 (BFSL) / < ± 0,6 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
Linearity deviation [% of the span]: | < ± 0,5; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,1; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,25; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,25; (0...80 °C) |
Response time [ms]: | < 1.5 |
Damping for the switching output dAP [s]: | 0.01...4 |
Damping for the analogue output dAA [s]: | 0.01...4 |
Max. response time analogue output [ms]: | 3 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
Ambient temperature [°C]: | -25...80 |
Note on ambient temperature: | Medium temperature: ≤ 160 °C |
Ambient temperature [°C]: | -25...65 |
Note on ambient temperature: | Medium temperature: ≤ 200 °C |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65 |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 167.14 |
Weight [g]: | 404.5 |
Materials: | stainless steel (1.4301 / 304); stainless steel (1.4435 / 316L); PC; PBT; PEI; PTFE |
Materials (wetted parts): | stainless steel (1.4435 / 316L) |
Min. pressure cycles: | 10 million |
Process connection: | threaded connection G 1/2 external thread |
Fill fluid for pressure transfer: | NEOBEE (food grade, FDA compliant) |
Display: | Display unit 3 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | 3 x LED, green |
switching status: | 2 x LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.40 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |