Ifm PT9542

Pressure transmitter. PT-100-SBG14-B-DVG/US/ /W

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Reliable detection of system pressure in industrial and mobile applications. High shock and vibration resistance. Excellent repeatability and low linearity error. Lifespan of more than 50 million pressure cycles. Compact and robust stainless steel housing for use where space is restricted

Technical parameters

Output signal: analogue signal
Measuring range: 0...100 bar 0...1450 psi 0...10 MPa
0...100 bar: 0...1450 psi
Process connection: threaded connection G 1/4 external thread
Application: for industrial applications
Media: liquids and gases
Medium temperature [°C]: -25...90
Min. bursting pressure: 1000 bar 14500 psi 100 MPa
1000 bar: 14500 psi
Pressure rating: 200 bar 2900 psi 20 Mpa
200 bar: 2900 psi
Type of pressure: relative pressure
Operating voltage [V]: 16...36 DC
Current consumption [mA]: < 6
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Number of inputs and outputs: Number of analogue outputs: 1
Total number of outputs: 1
Output signal: analogue signal
Number of analogue outputs: 1
Analogue voltage output [V]: 0...10
Min. load resistance [Ω]: 2000
Measuring range: 0...100 bar 0...1450 psi 0...10 MPa
0...100 bar: 0...1450 psi
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 1,0; (incl. drift when overtightened, zero point and span error)
Linearity deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS)
Hysteresis deviation [% of the span]: < ± 0,2
Long-term stability [% of the span]: < ± 0,1; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,1; (-25...90 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,1; (-25...90 °C)
Step response time analogue output [ms]: 3
Ambient temperature [°C]: -25...90
Storage temperature [°C]: -40...100
Protection: IP 67; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 4 kV coupling clamp
EN 61000-4-5 Surge: 1 kV signal for DC units
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 1116
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 81.55
Materials: stainless steel (1.4404 / 316L); PA
Materials (wetted parts): stainless steel (1.4404 / 316L); FKM
Min. pressure cycles: 50 million
Process connection: threaded connection G 1/4 external thread
Restrictor element integrated: no (can be retrofitted)
Remarks: BFSL = Best Fit Straight Line LS = limit value setting
Notes: discontinued article
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: RO
EAN:
Weight: 0.08 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m