PT5501
Pressure transmitter. PT-250-SEG14-A-ZVG/US
For the reliable detection of the system pressure in mobile machines. Robust stainless steel housing with high shock and vibration resistance. Compact housing for use where space is restricted. Lifespan of more than 60 million pressure cycles. With long-term stability thanks to high repeatability and low linearity error
Output signal: | analogue signal |
Measuring range: | 0...250 bar 0...3625 psi 0...25 MPa |
0...250 bar: | 0...3625 psi |
Process connection: | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) |
Application: | for mobile applications |
Media: | liquids and gases |
Medium temperature [°C]: | -40...125 |
Min. bursting pressure: | 1200 bar 17400 psi 120 MPa |
1200 bar: | 17400 psi |
Pressure rating: | 625 bar 9060 psi 62.5 Mpa |
625 bar: | 9060 psi |
Note on pressure rating: | static |
Vacuum resistance [mbar]: | -1000 |
Type of pressure: | relative pressure |
Operating voltage [V]: | 8...32 DC |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Number of inputs and outputs: | Number of analogue outputs: 1 |
Total number of outputs: | 1 |
Output signal: | analogue signal |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | (Ub - 8 V) / 21,5 mA |
Short-circuit proof: | yes |
Overload protection: | yes |
Measuring range: | 0...250 bar 0...3625 psi 0...25 MPa |
0...250 bar: | 0...3625 psi |
Repeatability [% of the span]: | < ± 0,05; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,8; (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis) |
Linearity deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
Hysteresis deviation [% of the span]: | < ± 0,2 |
Long-term stability [% of the span]: | < ± 0,1; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
Step response time analogue output [ms]: | 2 |
Ambient temperature [°C]: | -40...100 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 69K |
EMC: | compliant with UN ECE R10, rev. 5 (E1 compliant) ISO 11452-2 100 V/m DIN EN 61326-1 |
compliant with UN ECE R10, rev. 5: | (E1 compliant) |
ISO 11452-2: | 100 V/m |
Shock resistance: | DIN EN 60068-2-27 500 g (1 ms) |
DIN EN 60068-2-27: | 500 g (1 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 704 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 59 |
Materials: | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI |
Materials (wetted parts): | 1.4542 (17-4 PH / 630) |
Min. pressure cycles: | 60 million; (at 1.2 times nominal pressure) |
Tightening torque [Nm]: | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection: | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) |
Process connection sealing: | HNBR (to DIN 3869) |
Restrictor element integrated: | yes |
Remarks: | BFSL = Best Fit Straight Line LS = limit value setting |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Maximum cable length: 30 m |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.06 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |