PT3550
Pressure transmitter. PT-400-SBG14-A-ZVG/US/ /W
Reliable detection of system pressure in industrial and mobile applications. High shock and vibration resistance. Excellent repeatability and low linearity error. Lifespan of more than 50 million pressure cycles. Compact and robust stainless steel housing for use where space is restricted
Output signal: | analogue signal |
Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa |
0...400 bar: | 0...5800 psi |
Process connection: | threaded connection G 1/4 external thread |
Application: | for mobile applications |
Media: | liquids and gases |
Medium temperature [°C]: | -25...90; (on request: -40...100 °C) |
Min. bursting pressure: | 1600 bar 23200 psi 160 MPa |
1600 bar: | 23200 psi |
Pressure rating: | 600 bar 8700 psi 60 Mpa |
600 bar: | 8700 psi |
Type of pressure: | relative pressure |
Operating voltage [V]: | 8.5...36 DC |
Min. insulation resistance [MΩ]: | 100; (80 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Number of inputs and outputs: | Number of analogue outputs: 1 |
Total number of outputs: | 1 |
Output signal: | analogue signal |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 775; (Ub = 24 V; (Ub - 8,5 V) / 20 mA) |
Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa |
0...400 bar: | 0...5800 psi |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 1,0; (incl. drift when overtightened, zero point and span error) |
Linearity deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
Hysteresis deviation [% of the span]: | < ± 0,2 |
Long-term stability [% of the span]: | < ± 0,1; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1; (-25...90 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,1; (-25...90 °C) |
Step response time analogue output [ms]: | 8 |
Ambient temperature [°C]: | -25...90 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 69K |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD immunity according to the automotive directive 1995/54/EC, 2004/104 EC, 2005/83/EC ISO 11452-2 100 V/m ISO 11452-4 100 mA / severity level 4 ISO 7637-2 severity level 4 radiation of interference CISPR 25 EN 61000-6-1 EN 61000-6-4 |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
immunity: | according to the automotive directive 1995/54/EC, 2004/104 EC, 2005/83/EC |
ISO 11452-2: | 100 V/m |
ISO 11452-4: | 100 mA / severity level 4 |
ISO 7637-2: | severity level 4 |
radiation of interference: | CISPR 25 |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 1494 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 82.5 |
Materials: | stainless steel (1.4404 / 316L); PA |
Materials (wetted parts): | stainless steel (1.4404 / 316L); Sealing: FKM |
Min. pressure cycles: | 50 million |
Process connection: | threaded connection G 1/4 external thread |
Restrictor element integrated: | yes |
Remarks: | BFSL = Best Fit Straight Line LS = limit value setting |
Notes: | discontinued article |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | RO |
EAN: | |
Weight: | 0.08 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |