Ifm PQ3809

Pressure sensor for pneumatics. PQ-1-1-KHR18-KFPKG/AS/

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Reliable monitoring of the system pressure in pneumatics and in compressed air systems. Very high overpressure and vacuum resistance. Clearly visible slanted LED display. Red/green display for clear identification of the acceptable range. With programmable switching output and analogue output

Technical parameters

Output signal: switching signal; analogue signal; IO-Link; (configurable)
Measuring range: -1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa
-1...1 bar: -1000...1000 mbar
Process connection: threaded connection G 1/8 internal thread internal thread:M5
Special feature: Gold-plated contacts
Application: for industrial applications
Conditionally suitable for: other media on request
Medium temperature [°C]: 0...60
Min. bursting pressure: 30 bar 435 psi 886 inHg 3000 kPa
30 bar: 435 psi
Note on min. burst pressure: max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa
Pressure rating: 20 bar 290 psi 591 inHg 2000 kPa
20 bar: 290 psi
Vacuum resistance [mbar]: -1000
Type of pressure: relative pressure; differential pressure; vacuum
Operating voltage [V]: 18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 50
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Overvoltage protection: yes; (< 40 V)
Power-on delay time [s]: 0.5
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 1
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 100
Switching frequency DC [Hz]: < 100
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 500
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Measuring range: -1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa
-1...1 bar: -1000...1000 mbar
Set point SP: -0.98...1 bar -14.2...14.6 psi -28.8...29.4 inHg -98...100 kPa
-0.98...1 bar: -14.2...14.6 psi
Reset point rP: -0.99...0.99 bar -14.4...14.4 psi -29.1...29.1 inHg -99...99 kPa
-0.99...0.99 bar: -14.4...14.4 psi
In steps of: 0.01 bar 0.2 psi 0.3 inHg 1 kPa
0.01 bar: 0.2 psi
Switch point accuracy [% of the span]: < ± 0,5
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,25
Long-term stability [% of the span]: < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: 0,2; (0...60 °C)
Temperature coefficient span [% of the span / 10 K]: 0,2; (0...60 °C)
Response time [ms]: < 6
Delay time programmable dS, dr [s]: 0; 0,002...5
Step response time analogue output [ms]: 6
Parameter setting options: hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 FDIS
IO-Link device ID: 366 d / 00 01 6E h
Profiles: Smart Sensor: Process Data Variable; Device Identification
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: 0...70
Storage temperature [°C]: -25...85
Protection: IP 65
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 437
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [K40]: 86.5
Materials: PBT; FKM; polyester
Materials (wetted parts): brass; FKM; silicon (coated); PBT
Min. pressure cycles: 50 million
Process connection: threaded connection G 1/8 internal thread internal thread:M5
Display: Display unit 4 x LED, green switching status 1 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
Display unit: 4 x LED, green
switching status: 1 x LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
Display unit: bar; kPa; psi; inHg
Pack quantity: 1 pcs.
Connection: Connector: 1 x M8; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: RO
EAN:
Weight: 0.09 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m