PPA020
Pressure switch with ceramic measuring cell. PPA400-SBR14-ASIVG/US/ /V
Conversion of system pressure into digitally coded analogue values. Reliable data transmission via AS-i interface. Robust design for use in harsh industrial environments. High shock and vibration resistance. Lifespan of more than 100 million pressure cycles
Measuring range [bar]: | 0...400 |
Process connection: | threaded connection G 1/4 internal thread |
Special feature: | Gold-plated contacts |
Design: | analogue value (16 bit value incl. sign) |
Application: | for industrial applications |
Media: | Liquids |
Conditionally suitable for: | use in gases at pressures > 25 bar only on request |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure [bar]: | 1000 |
Pressure rating [bar]: | 600 |
Type of pressure: | relative pressure |
Operating voltage [V]: | 18...31.6 DC |
Current consumption [mA]: | < 25 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.3 |
Integrated watchdog: | yes |
Electrical design: | AS-i |
Overload protection: | yes |
Measuring range [bar]: | 0...400 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,5; (linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Hysteresis deviation [% of the span]: | < ± 0,5 |
Long-term stability [% of the span]: | < ± 0,1; (per year) |
Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K]: | 0,3; (0...70 °C) |
Ambient temperature [°C]: | -25...70 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD Klasse B EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 1 kV Class A / 2 kV class B EN 55011 emission Level B |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD Klasse B |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 1 kV Class A / 2 kV class B |
EN 55011 emission: | Level B |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 293 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 248 |
Materials: | stainless steel (1.4301 / 304); PA |
Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1/4 internal thread |
Restrictor element integrated: | yes |
Display: | operation LED, green failure LED, red |
operation: | LED, green |
failure: | LED, red |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.25 kg |
Length: | 0.00 m |
Width: | 0.00 m |