PP7550
Pressure switch with ceramic measuring cell. PP-400-SBG14-QFPKG/US/ /V
Robust design for use in harsh industrial environments. Two switching outputs, one of which can be configured as diagnostic output. High shock and vibration resistance. Lifespan of more than 100 million pressure cycles. User-friendly communication via IO-Link
Output signal: | switching signal; IO-Link; (configurable) |
Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa |
0...400 bar: | 0...5800 psi |
Process connection: | threaded connection G 1/4 external thread internal thread:M5 |
Application: | for industrial applications |
Media: | liquids and gases |
Conditionally suitable for: | use in gases at pressures > 25 bar only on request |
Medium temperature [°C]: | -25...90 |
Min. bursting pressure: | 1000 bar 14500 psi 100 MPa |
1000 bar: | 14500 psi |
Pressure rating: | 600 bar 8700 psi 60 Mpa |
600 bar: | 8700 psi |
Type of pressure: | relative pressure |
Operating voltage [V]: | 9.6...36 DC; (communication mode: 18...32) |
Current consumption [mA]: | < 45 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.3 |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal; IO-Link; (configurable) |
Electrical design: | PNP |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | 170 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa |
0...400 bar: | 0...5800 psi |
Set point SP: | 4...400 bar 60...5790 psi 0.4...40 MPa |
4...400 bar: | 60...5790 psi |
Reset point rP: | 2...398 bar 30...5760 psi 0.2...39.8 MPa |
2...398 bar: | 30...5760 psi |
In steps of: | 2 bar 30 psi 0.2 MPa |
2 bar: | 30 psi |
Factory setting: | SP1 = 100 bar rP1 = 92 bar SP2 = 300 bar rP2 = 292 bar OUT1 = Hno OUT2 = Hno |
Switch point accuracy [% of the span]: | < ± 0,5 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span]: | < ± 0,1 |
Long-term stability [% of the span]: | < ± 0,1; (per year) |
Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | 0,2; (0...80 °C) |
Response time [ms]: | < 3 |
Damping for the switching output dAP in steps [s]: | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.0 |
IO-Link device ID: | 2 d / 00 00 02 h |
Profiles: | no profile |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 1 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 2.3 |
Ambient temperature [°C]: | -25...85 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 68; (7 days / 1 m water depth / 0.1 bar) |
EMC: | immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V immunity according to the automotive directive 1995/54/EC / 04/104EG / 05/83/EG absorber chamber test to ISO 11452-2: 80 V/m EN 50155 Klasse T3, C1, S1 |
immunity: | EN 61000-6-2 |
EN 61000-4-2 ESD: | 4 kV contact discharge / 15 kV air discharge |
EN 61000-4-3 HF radiated: | 20 V/m |
EN 61000-4-4 Burst: | 4 kV coupling clamp |
EN 61000-4-5 Surge: | 0,5 kV supply / 1 kV signal for DC units |
EN 61000-4-6 HF conducted: | 10 V |
immunity: | according to the automotive directive 1995/54/EC / 04/104EG / 05/83/EG |
absorber chamber test to ISO 11452-2:: | 80 V/m |
EN 50155: | Klasse T3, C1, S1 |
Shock resistance: | DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3 |
DIN IEC 60068-2-27 / DIN IEC 60068-2-29: | 1000 g |
DIN EN 61373: | category 3 |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2 |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
DIN EN 60068-2-64: | 14 g |
DIN EN 61373: | category 2 |
MTTF [years]: | 310 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 220.2 |
Materials: | stainless steel (1.4301 / 304); FKM; EPDM/X; PA |
Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1/4 external thread internal thread:M5 |
Restrictor element integrated: | yes |
Display: | operation 2 x LED, green switching status 2 x LED, yellow |
operation: | 2 x LED, green |
switching status: | 2 x LED, yellow |
Teach function: | yes |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | RO |
EAN: | |
Weight: | 0.22 kg |
Length: | 0.00 m |