Ifm PP004E

Pressure switch with ceramic measuring cell. PP-010-RBG14-QFPKG/US/ /V

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Suited for use in mobile machines. Two switching outputs, one of which can be configured as diagnostic output. High shock and vibration resistance. Excellent EMC resistance. User-friendly communication via IO-Link

Technical parameters

Output signal: switching signal; IO-Link; (configurable)
Measuring range: -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa
-1...10 bar: -14.5...145 psi
Process connection: threaded connection G 1/4 external thread internal thread:M5
Application: for mobile applications
Media: liquids and gases
Medium temperature [°C]: -25...90
Min. bursting pressure: 150 bar 2175 psi 15 MPa
150 bar: 2175 psi
Pressure rating: 75 bar 1087 psi 7.5 Mpa
75 bar: 1087 psi
Type of pressure: relative pressure; vacuum
Operating voltage [V]: 9.6...36 DC; (communication mode: 18...32)
Current consumption [mA]: < 45
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 0.3
Number of inputs and outputs: Number of digital outputs: 2
Total number of outputs: 2
Output signal: switching signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: 170
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa
-1...10 bar: -14.5...145 psi
Set point SP: -0.9...10 bar -13...145 psi -0.09...1 MPa
-0.9...10 bar: -13...145 psi
Reset point rP: -0.95...9.95 bar -14...144 psi -0.095...0.995 MPa
-0.95...9.95 bar: -14...144 psi
In steps of: 0.05 bar 1 psi 0.005 MPa
0.05 bar: 1 psi
Factory setting: SP1 = 2.50 bar rP1 = 2.30 bar SP2 = 7.50 bar rP2 = 7.30 bar OUT1 = Hno OUT2 = Hno
Switch point accuracy [% of the span]: < ± 0,5
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,1
Long-term stability [% of the span]: < ± 0,1; (per year)
Temperature coefficient zero point [% of the span / 10 K]: 0,2; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]: 0,2; (0...80 °C)
Response time [ms]: < 3
Damping for the switching output dAP in steps [s]: 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.0
IO-Link device ID: 6 d / 00 00 06 h
Profiles: no profile
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...85
Storage temperature [°C]: -40...100
Protection: IP 68; (7 days / 1 m water depth / 0.1 bar)
EMC: immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V immunity ECE R 10, Rev. 5 absorber chamber test to ISO 11452-2: 80 V/m EN 50155 Klasse T3, C1, S1
immunity: EN 61000-6-2
EN 61000-4-2 ESD: 4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated: 20 V/m
EN 61000-4-4 Burst: 4 kV coupling clamp
EN 61000-4-5 Surge: 0,5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted: 10 V
immunity: ECE R 10, Rev. 5
absorber chamber test to ISO 11452-2:: 80 V/m
EN 50155: Klasse T3, C1, S1
Shock resistance: DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3
DIN IEC 60068-2-27 / DIN IEC 60068-2-29: 1000 g
DIN EN 61373: category 3
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2
DIN IEC 68-2-6: 20 g (10...2000 Hz)
DIN EN 60068-2-64: 14 g
DIN EN 61373: category 2
MTTF [years]: 310
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 224
Materials: stainless steel (1.4301 / 304); FKM; EPDM/X; PA
Materials (wetted parts): stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles: 100 million
Process connection: threaded connection G 1/4 external thread internal thread:M5
Restrictor element integrated: no (can be retrofitted)
Display: operation 2 x LED, green switching status 2 x LED, yellow
operation: 2 x LED, green
switching status: 2 x LED, yellow
Teach function: yes
Remarks: with reference to UL: "limited voltage" with overcurrent protection in accordance with UL508
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: RO
EAN:
Weight: 0.22 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m