PP000E
Pressure switch with ceramic measuring cell. PP-400-SBG14-QFPKG/US/ /V
Suited for use in mobile machines. Two switching outputs, one of which can be configured as diagnostic output. High shock and vibration resistance. Excellent EMC resistance. User-friendly communication via IO-Link
| Output signal: | switching signal; IO-Link; (configurable) | 
| Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa | 
| 0...400 bar: | 0...5800 psi | 
| Process connection: | threaded connection G 1/4 external thread internal thread:M5 | 
| Application: | for mobile applications | 
| Media: | liquids and gases | 
| Conditionally suitable for: | use in gases at pressures > 25 bar only on request | 
| Medium temperature [°C]: | -25...90 | 
| Min. bursting pressure: | 1000 bar 14500 psi 100 MPa | 
| 1000 bar: | 14500 psi | 
| Pressure rating: | 600 bar 8700 psi 60 Mpa | 
| 600 bar: | 8700 psi | 
| Type of pressure: | relative pressure | 
| Operating voltage [V]: | 9.6...36 DC; (communication mode: 18...32) | 
| Current consumption [mA]: | < 45 | 
| Min. insulation resistance [MΩ]: | 100; (500 V DC) | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Power-on delay time [s]: | 0.3 | 
| Number of inputs and outputs: | Number of digital outputs: 2 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal; IO-Link; (configurable) | 
| Electrical design: | PNP | 
| Number of digital outputs: | 2 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Permanent current rating of switching output DC [mA]: | 250 | 
| Switching frequency DC [Hz]: | 170 | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Overload protection: | yes | 
| Measuring range: | 0...400 bar 0...5800 psi 0...40 MPa | 
| 0...400 bar: | 0...5800 psi | 
| Set point SP: | 4...400 bar 60...5790 psi 0.4...40 MPa | 
| 4...400 bar: | 60...5790 psi | 
| Reset point rP: | 2...398 bar 30...5760 psi 0.2...39.8 MPa | 
| 2...398 bar: | 30...5760 psi | 
| In steps of: | 2 bar 30 psi 0.2 MPa | 
| 2 bar: | 30 psi | 
| Factory setting: | SP1 = 100 bar rP1 = 92 bar SP2 = 300 bar rP2 = 292 bar OUT1 = Hno OUT2 = Hno | 
| Switch point accuracy [% of the span]: | < ± 0,5 | 
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) | 
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | 
| Hysteresis deviation [% of the span]: | < ± 0,1 | 
| Long-term stability [% of the span]: | < ± 0,1; (per year) | 
| Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...80 °C) | 
| Temperature coefficient span [% of the span / 10 K]: | 0,2; (0...80 °C) | 
| Response time [ms]: | < 3 | 
| Damping for the switching output dAP in steps [s]: | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 | 
| Communication interface: | IO-Link | 
| Transmission type: | COM2 (38,4 kBaud) | 
| IO-Link revision: | 1.0 | 
| IO-Link device ID: | 2 d / 00 00 02 h | 
| Profiles: | no profile | 
| SIO mode: | yes | 
| Required master port type: | A | 
| Process data analogue: | 1 | 
| Process data binary: | 2 | 
| Min. process cycle time [ms]: | 2.3 | 
| Ambient temperature [°C]: | -25...85 | 
| Storage temperature [°C]: | -40...100 | 
| Protection: | IP 68; (7 days / 1 m water depth / 0.1 bar) | 
| EMC: | immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V immunity ECE R 10, Rev. 5 absorber chamber test to ISO 11452-2: 80 V/m EN 50155 Klasse T3, C1, S1 | 
| immunity: | EN 61000-6-2 | 
| EN 61000-4-2 ESD: | 4 kV contact discharge / 15 kV air discharge | 
| EN 61000-4-3 HF radiated: | 20 V/m | 
| EN 61000-4-4 Burst: | 4 kV coupling clamp | 
| EN 61000-4-5 Surge: | 0,5 kV supply / 1 kV signal for DC units | 
| EN 61000-4-6 HF conducted: | 10 V | 
| immunity: | ECE R 10, Rev. 5 | 
| absorber chamber test to ISO 11452-2:: | 80 V/m | 
| EN 50155: | Klasse T3, C1, S1 | 
| Shock resistance: | DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3 | 
| DIN IEC 60068-2-27 / DIN IEC 60068-2-29: | 1000 g | 
| DIN EN 61373: | category 3 | 
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2 | 
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) | 
| DIN EN 60068-2-64: | 14 g | 
| DIN EN 61373: | category 2 | 
| MTTF [years]: | 310 | 
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | 
| Weight [g]: | 218.5 | 
| Materials: | stainless steel (1.4301 / 304); FKM; EPDM/X; PA | 
| Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM | 
| Min. pressure cycles: | 100 million | 
| Process connection: | threaded connection G 1/4 external thread internal thread:M5 | 
| Restrictor element integrated: | yes | 
| Display: | operation 2 x LED, green switching status 2 x LED, yellow | 
| operation: | 2 x LED, green | 
| switching status: | 2 x LED, yellow | 
| Teach function: | yes | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M12 | 
| ECCN: | |
| Country of Origin: | DE | 
| EAN: | |
| Weight: | 0.22 kg | 
| Length: | 0.00 m | 
| Width: | 0.00 m | 
| Height: | 0.00 m |