PN7834
Pressure sensor with display. PN-010-RBR18-QFRKG/US/ /V
Two switching outputs, one of which can be configured as diagnostic output. For use in pneumatic applications. Clearly visible 4-digit LED display. Differential pressure measurement without the need to connect a second pressure pick-up. Country-specific pressure units selectable
| Output signal: | switching signal | 
| Measuring range: | -1...10 bar -14.5...145 psi -0.1...1 MPa | 
| -1...10 bar: | -14.5...145 psi | 
| Process connection: | threaded connection G 1/8 internal thread | 
| Special feature: | Gold-plated contacts | 
| Application: | for industrial applications | 
| Media: | compressed air | 
| Conditionally suitable for: | other media on request | 
| Medium temperature [°C]: | 0...60 | 
| Min. bursting pressure: | 30 bar 435 psi 3 MPa | 
| 30 bar: | 435 psi | 
| Pressure rating: | 20 bar 290 psi 2 Mpa | 
| 20 bar: | 290 psi | 
| Type of pressure: | relative pressure; vacuum | 
| Operating voltage [V]: | 18...36 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA]: | < 50 | 
| Min. insulation resistance [MΩ]: | 100; (500 V DC) | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Overvoltage protection: | yes; (< 40 V) | 
| Power-on delay time [s]: | 0.3 | 
| Integrated watchdog: | yes | 
| Number of inputs and outputs: | Number of digital outputs: 2 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal | 
| Electrical design: | PNP/NPN | 
| Number of digital outputs: | 2 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Permanent current rating of switching output DC [mA]: | 250 | 
| Switching frequency DC [Hz]: | < 170 | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Measuring range: | -1...10 bar -14.5...145 psi -0.1...1 MPa | 
| -1...10 bar: | -14.5...145 psi | 
| Set point SP: | -0.9...10 bar -13...145 psi -0.09...1 MPa | 
| -0.9...10 bar: | -13...145 psi | 
| Reset point rP: | -0.95...9.95 bar -14...144 psi -0.095...0.995 MPa | 
| -0.95...9.95 bar: | -14...144 psi | 
| In steps of: | 0.05 bar 1 psi 0.005 MPa | 
| 0.05 bar: | 1 psi | 
| Factory setting: | SP1 = 2.50 bar rP1 = 2.30 bar SP2 = 7.50 bar rP2 = 7.30 bar | 
| Switch point accuracy [% of the span]: | < ± 0,5 | 
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) | 
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | 
| Hysteresis deviation [% of the span]: | < ± 0,25 | 
| Long-term stability [% of the span]: | < ± 0,05; (per 6 months) | 
| Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...60 °C) | 
| Temperature coefficient span [% of the span / 10 K]: | 0,2; (0...60 °C) | 
| Delay time programmable dS, dr [s]: | 0; 0,2...50 | 
| Parameter setting options: | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit | 
| Ambient temperature [°C]: | -25...85 | 
| Storage temperature [°C]: | -25...85 | 
| Protection: | IP 67 | 
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V | 
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | 
| EN 61000-4-3 HF radiated: | 10 V/m | 
| EN 61000-4-4 Burst: | 2 kV | 
| EN 61000-4-5 Surge: | 0,5/1 kV | 
| EN 61000-4-6 HF conducted: | 10 V | 
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) | 
| DIN IEC 68-2-27: | 50 g (11 ms) | 
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) | 
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) | 
| MTTF [years]: | 284 | 
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | 
| Weight [g]: | 173.5 | 
| Materials: | stainless steel (1.4301 / 304); PPS; PC; PBT; PEI; FKM | 
| Materials (wetted parts): | stainless steel (1.4567 / 304Cu); brass; FKM; PPS; silicon (coated) | 
| Min. pressure cycles: | 50 million | 
| Process connection: | threaded connection G 1/8 internal thread | 
| Display: | Display unit 3 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit | 
| Display unit: | 3 x LED, green | 
| switching status: | 2 x LED, yellow | 
| function display: | alphanumeric display, 4-digit | 
| Accessories (optional): | mounting set for DIN rail: TH 35-7,5 / EN60715, E37340 Adapter: R1/8 - R1/8, E37350 Thread extension: 1/8", E30075 push-in air fitting for tube: Ø 6 mm, E30076 push-in air fitting for tube: Ø 8 mm, E30077 | 
| Pack quantity: | 1 pcs. | 
| ECCN: | |
| Country of Origin: | RO | 
| EAN: | |
| Weight: | 0.17 kg | 
| Length: | 0.00 m | 
| Width: | 0.00 m | 
| Height: | 0.00 m |