PN7692
Pressure sensor with display. PN-100-SEN14-QFRKG/US/ /V
Two switching outputs, one of them with IO-Link communication interface. Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments
Output signal: | switching signal; IO-Link; (configurable) |
Measuring range: | 0...100 bar 0...1450 psi 0...10 MPa |
0...100 bar: | 0...1450 psi |
Process connection: | threaded connection 1/4" NPT external thread |
Special feature: | Gold-plated contacts |
Measuring element: | ceramic-capacitive pressure measuring cell |
Application: | for industrial applications |
Media: | Liquids |
Conditionally suitable for: | use in gases at pressures > 25 bar only on request |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 650 bar 9400 psi 65 MPa |
650 bar: | 9400 psi |
Pressure rating: | 300 bar 4350 psi 30 Mpa |
300 bar: | 4350 psi |
Type of pressure: | relative pressure |
MAWP (for applications according to CRN) [bar]: | 125 |
Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 35 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.3 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 150; (200 (...60 °C) 250 (...40 °C)) |
Switching frequency DC [Hz]: | < 170 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...100 bar 0...1450 psi 0...10 MPa |
0...100 bar: | 0...1450 psi |
Set point SP: | 1...100 bar 10...1450 psi 0.1...10 MPa |
1...100 bar: | 10...1450 psi |
Reset point rP: | 0.5...99.5 bar 5...1445 psi 0.05...9.95 MPa |
0.5...99.5 bar: | 5...1445 psi |
Min. difference between SP and rP: | 0.5 bar 10 psi 0.05 MPa |
0.5 bar: | 10 psi |
In steps of: | 0.5 bar 5 psi 0.05 MPa |
0.5 bar: | 5 psi |
Set point SP: | 0.8...100 bar 12...1450 psi 0.08...10 MPa |
0.8...100 bar: | 12...1450 psi |
Reset point rP: | 0.3...99.5 bar 5...1443 psi 0.03...9.95 MPa |
0.3...99.5 bar: | 5...1443 psi |
Min. difference between SP and rP: | 0.5 bar 8 psi 0.05 MPa |
0.5 bar: | 8 psi |
In steps of: | 0.1 bar 1 psi 0.01 MPa |
0.1 bar: | 1 psi |
Switch point accuracy [% of the span]: | < ± 0,5 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span]: | < ± 0,25 |
Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (-0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (-0...80 °C) |
Response time [ms]: | < 3 |
Delay time programmable dS, dr [s]: | 0...50 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
SIO mode: | yes |
Required master port type: | A; (when pin 2 not connected: B) |
Supported DeviceIDs: | Type of operation DeviceID Factory setting / CMPT = 2 452 d / 00 01 c4 h Status_B High Resolution / CMPT = 3 629 d / 00 02 75 h |
Type of operation: | DeviceID |
Factory setting / CMPT = 2: | 452 d / 00 01 c4 h |
Status_B High Resolution / CMPT = 3: | 629 d / 00 02 75 h |
Note: | For further information please see the IODD PDF file under "Downloads" |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms]: | 2.3 |
IO-Link resolution pressure [bar]: | 0.1 |
IO-Link resolution pressure [MPa]: | 0.01 |
IO-Link process data (cyclical): | function bit length pressure 14 binary switching information 2 |
function: | bit length |
pressure: | 14 |
binary switching information: | 2 |
IO-Link functions (acyclical): | application specific tag |
Profiles: | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms]: | 3 |
IO-Link resolution pressure [bar]: | 0.05 |
IO-Link resolution pressure [MPa]: | 0.005 |
IO-Link process data (cyclical): | function bit length pressure 16 device status 4 binary switching information 2 |
function: | bit length |
pressure: | 16 |
device status: | 4 |
binary switching information: | 2 |
IO-Link functions (acyclical): | application specific tag |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65; IP 67 |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 286 |
UL approval: | UL Approval no. J002 |
UL Approval no.: | J002 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 282 |
Materials: | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts): | stainless steel (1.4404 / 316L); ceramics; FKM |
Min. pressure cycles: | 100 million |
Tightening torque [Nm]: | 2...3 turns after hand-fastening; recommended tightening torque; depends on lubrication, seal and pressure rating |
Process connection: | threaded connection 1/4" NPT external thread |
Restrictor element integrated: | no (can be retrofitted) |
Display: | Display unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit |
Display unit: | 3 x LED, green (bar, psi, MPa) |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, red/green 4-digit |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.28 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |