Ifm PN7294

Pressure sensor with display. PN-010-REN14-QFRKG/US/ /V

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Two switching outputs, one of them with IO-Link communication interface. Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments

Technical parameters

Output signal: switching signal; IO-Link; (configurable)
Measuring range: -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa
-1...10 bar: -14.5...145 psi
Process connection: threaded connection 1/4" NPT internal thread
Special feature: Gold-plated contacts
Measuring element: ceramic-capacitive pressure measuring cell
Application: for industrial applications
Media: liquids and gases
Medium temperature [°C]: -25...80
Min. bursting pressure: 150 bar 2175 psi 15 MPa
150 bar: 2175 psi
Pressure rating: 75 bar 1087 psi 7.5 Mpa
75 bar: 1087 psi
Type of pressure: relative pressure; vacuum
MAWP (for applications according to CRN) [bar]: 50
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 35
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: < 0.3
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 2
Total number of outputs: 2
Output signal: switching signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC [Hz]: < 170
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa
-1...10 bar: -14.5...145 psi
Set point SP: -0.9...10 bar -13.5...145 psi -0.09...1 MPa
-0.9...10 bar: -13.5...145 psi
Reset point rP: -0.95...9.95 bar -14...144.5 psi -0.095...0.995 MPa
-0.95...9.95 bar: -14...144.5 psi
Min. difference between SP and rP: 0.05 bar 1 psi 0.005 MPa
0.05 bar: 1 psi
In steps of: 0.05 bar 0.5 psi 0.005 MPa
0.05 bar: 0.5 psi
Set point SP: -0.92...10 bar -13.3...145 psi -0.092...1 MPa
-0.92...10 bar: -13.3...145 psi
Reset point rP: -0.97...9.95 bar -14...144.3 psi -0.097...9.995 MPa
-0.97...9.95 bar: -14...144.3 psi
Min. difference between SP and rP: 0.05 bar 0.8 psi 0.005 MPa
0.05 bar: 0.8 psi
In steps of: 0.01 bar 0.1 psi 0.001 MPa
0.01 bar: 0.1 psi
Switch point accuracy [% of the span]: < ± 0,5
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,25
Long-term stability [% of the span]: < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,2; (-0...80 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,2; (-0...80 °C)
Response time [ms]: < 3
Delay time programmable dS, dr [s]: 0...50
Parameter setting options: hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
SIO mode: yes
Required master port type: A; (when pin 2 not connected: B)
Supported DeviceIDs: Type of operation DeviceID Factory setting / CMPT = 2 454 d / 00 01 c6 h Status_B High Resolution / CMPT = 3 632 d / 00 02 78 h
Type of operation: DeviceID
Factory setting / CMPT = 2: 454 d / 00 01 c6 h
Status_B High Resolution / CMPT = 3: 632 d / 00 02 78 h
Note: For further information please see the IODD PDF file under "Downloads"
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms]: 2.3
IO-Link resolution pressure [bar]: 0.01
IO-Link resolution pressure [MPa]: 0.001
IO-Link process data (cyclical): function bit length pressure 14 binary switching information 2
function: bit length
pressure: 14
binary switching information: 2
IO-Link functions (acyclical): application specific tag
Profiles: Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms]: 3
IO-Link resolution pressure [bar]: 0.005
IO-Link resolution pressure [MPa]: 0.0005
IO-Link process data (cyclical): function bit length pressure 16 device status 4 binary switching information 2
function: bit length
pressure: 16
device status: 4
binary switching information: 2
IO-Link functions (acyclical): application specific tag
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 65; IP 67
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 260
UL approval: UL Approval no. J001
UL Approval no.: J001
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 222
Materials: stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts): stainless steel (1.4404 / 316L); ceramics; FKM
Min. pressure cycles: 100 million
Tightening torque [Nm]: 2...3 turns after hand-fastening; recommended tightening torque; depends on lubrication, seal and pressure rating
Process connection: threaded connection 1/4" NPT internal thread
Restrictor element integrated: no (can be retrofitted)
Display: Display unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit
Display unit: 3 x LED, green (bar, psi, MPa)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.22 kg
Length: 0.00 m
Width: 0.00 m