PN5004
PN-010-RBR14-HFPKG/US/ /V
Pressure sensor with display. PN-010-RBR14-HFPKG/US/ /V
With long-term stability thanks to high overload protection. Lifespan of more than 100 million pressure cycles. Clearly visible 4-digit LED display. Country-specific pressure units selectable. Memory function for the highest measured system pressure
Output signal: | switching signal |
Measuring range: | -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa |
-1...10 bar: | -14.5...145 psi |
Process connection: | threaded connection G 1/4 internal thread |
Special feature: | Gold-plated contacts |
Application: | for industrial applications |
Media: | liquids and gases |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 150 bar 2175 psi 15 MPa |
150 bar: | 2175 psi |
Pressure rating: | 75 bar 1087 psi 7.5 Mpa |
75 bar: | 1087 psi |
Type of pressure: | relative pressure |
Operating voltage [V]: | 18...36 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 50 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Overvoltage protection: | yes; (< 40 V) |
Power-on delay time [s]: | 0.3 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1 |
Total number of outputs: | 1 |
Output signal: | switching signal |
Electrical design: | PNP |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | < 170 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Measuring range: | -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa |
-1...10 bar: | -14.5...145 psi |
Set point SP: | -0.9...10 bar -12...145 psi -0.09...1 MPa |
-0.9...10 bar: | -12...145 psi |
Reset point rP: | -0.95...9.95 bar -13...144 psi -0.095...0.995 MPa |
-0.95...9.95 bar: | -13...144 psi |
In steps of: | 0.05 bar 1 psi 0.005 MPa |
0.05 bar: | 1 psi |
Factory setting: | SP1 = 2.50 bar rP1 = 2.30 bar |
Switch point accuracy [% of the span]: | < ± 0,5 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span]: | < ± 0,25 |
Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (-20...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | 0,2; (-20...80 °C) |
Delay time programmable dS, dr [s]: | 0; 0,2...50 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5/1 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 231 |
Weight [g]: | 258.6 |
Materials: | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1/4 internal thread |
Display: | Display unit 3 x LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | 3 x LED, green |
switching status: | LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Notes: | discontinued article |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DEUTSCHLAND |
EAN: | |
Weight: | 0.26 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |