PN4224
Pressure sensor with display. PN-010-RBN14-HFBOW/LS/ /V
Potential-free Triac output for currents up to 2.5 A. For use in AC power mains. Country-specific pressure units selectable. Clearly visible 4-digit LED display. With long-term stability thanks to high overload protection
Output signal: | switching signal |
Measuring range: | 0...10 bar 0...145 psi 0...1000 kPa 0...1 MPa |
0...10 bar: | 0...145 psi |
Process connection: | threaded connection 1/4" NPT internal thread |
Application: | for industrial applications |
Media: | liquids and gases |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 150 bar 2175 psi 15000 kPa |
150 bar: | 2175 psi |
Pressure rating: | 75 bar 1088 psi 7500 kPa |
75 bar: | 1088 psi |
Type of pressure: | relative pressure |
Operating voltage tolerance [%]: | 5...10 |
Operating voltage [V]: | 85...265 AC |
Nominal voltage AC [V]: | < 250 |
Current consumption [mA]: | < 10 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | II |
Reverse polarity protection: | no |
Power-on delay time [s]: | 0.2 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1 |
Total number of outputs: | 1 |
Output signal: | switching signal |
Electrical design: | Triac |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output AC [V]: | 2 |
Permanent current rating of switching output AC [mA]: | 250; ((...70 °C) 1000 (...60 °C) 1500 (...45 °C) 2500 (...20 °C)) |
Switching frequency AC [Hz]: | < 160 |
Short-circuit proof: | no |
Overload protection: | no |
Measuring range: | 0...10 bar 0...145 psi 0...1000 kPa 0...1 MPa |
0...10 bar: | 0...145 psi |
Set point SP: | 0.1...9.99 bar 1...145 psi 10...999 kPa |
0.1...9.99 bar: | 1...145 psi |
Reset point rP: | 0.05...9.95 bar 1...144 psi 5...994 kPa |
0.05...9.95 bar: | 1...144 psi |
In steps of: | 0.01 bar 1 psi 1 kPa |
0.01 bar: | 1 psi |
Switch point accuracy [% of the span]: | < ± 1,0 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Linearity deviation [% of the span]: | < ± 0,5 |
Hysteresis deviation [% of the span]: | < ± 0,1 |
Long-term stability [% of the span]: | < ± 0,1; (per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (-25...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,3; (-25...80 °C) |
Delay time programmable dS, dr [s]: | 0, 0,2,...10, 11,...50 |
Damping for the switching output dAP [s]: | 0...4 |
Adjustment of the switch point: | programming button |
Parameter setting options: | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 224.58 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 388.5 |
Materials: | stainless steel (1.4301 / 304); PC; PBT; PA; FKM |
Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection 1/4" NPT internal thread |
Restrictor element integrated: | no (can be retrofitted) |
Display: | switching status LED, red function display 7-segment LED display measured values 7-segment LED display |
switching status: | LED, red |
function display: | 7-segment LED display |
measured values: | 7-segment LED display |
Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting |
Remarks: | n.c. = not used $ |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x 1/2" |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.39 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |