PN3597
Pressure sensor with display. PN-001BREG14-MFRKG/US/ /V
Two switching outputs, one of them programmable as IO-Link and one as analogue output. Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Measuring range: | 0...1 bar 0...1000 mbar 0...14.5 psi 0...29.5 inHg 0...100 kPa |
0...1 bar: | 0...1000 mbar |
Process connection: | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Special feature: | Gold-plated contacts |
Measuring element: | ceramic-capacitive pressure measuring cell |
Application: | for industrial applications |
Media: | liquids and gases |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 30000 mbar 450 psi 880 inHg 3000 kPa |
30000 mbar: | 450 psi |
Pressure rating: | 10000 mbar 145 psi 290 inHg 1000 kPa |
10000 mbar: | 145 psi |
Vacuum resistance [mbar]: | -1000 |
Type of pressure: | relative pressure |
Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 35 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.3 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design: | PNP |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 150; (200 (...60 °C) 250 (...40 °C)) |
Switching frequency DC [Hz]: | < 170 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 500 |
Analogue voltage output [V]: | 0...10 |
Min. load resistance [Ω]: | 2000 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...1 bar 0...1000 mbar 0...14.5 psi 0...29.5 inHg 0...100 kPa |
0...1 bar: | 0...1000 mbar |
Set point SP: | 10...1000 mbar 0.1...14.5 psi 0.2...29.5 inHg 1...100 kPa |
10...1000 mbar: | 0.1...14.5 psi |
Reset point rP: | 5...995 mbar 0.05...14.5 psi 0.1...29.4 inHg 0.5...99.5 kPa |
5...995 mbar: | 0.05...14.5 psi |
Min. difference between SP and rP: | 5 mbar 0.1 psi 0.2 inHg 0.5 kPa |
5 mbar: | 0.1 psi |
In steps of: | 5 mbar 0.05 psi 0.1 inHg 0.5 kPa |
5 mbar: | 0.05 psi |
Set point SP: | 8...1000 mbar 0.12...14.5 psi 0.2...29.5 inHg 0.8...100 kPa |
8...1000 mbar: | 0.12...14.5 psi |
Reset point rP: | 3...995 mbar 0.05...14.43 psi 0.1...29.4 inHg 0.3...99.5 kPa |
3...995 mbar: | 0.05...14.43 psi |
Min. difference between SP and rP: | 5 mbar 0.08 psi 0.2 inHg 0.5 kPa |
5 mbar: | 0.08 psi |
In steps of: | 1 mbar 0.01 psi 0.1 inHg 0.1 kPa |
1 mbar: | 0.01 psi |
Switch point accuracy [% of the span]: | < ± 0,5 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span]: | < ± 0,25 |
Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (-0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (-0...80 °C) |
Response time [ms]: | < 3 |
Delay time programmable dS, dr [s]: | 0...50 |
Damping for the switching output dAP [s]: | 0...4 |
Damping for the analogue output dAA [s]: | 0...4 |
Max. response time analogue output [ms]: | 3 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 1 |
Process data binary: | 1 |
Supported DeviceIDs: | Type of operation DeviceID Factory setting / CMPT = 2 433 d / 00 01 b1 h Status_B High Resolution / CMPT = 3 618 d / 00 02 6a h |
Type of operation: | DeviceID |
Factory setting / CMPT = 2: | 433 d / 00 01 b1 h |
Status_B High Resolution / CMPT = 3: | 618 d / 00 02 6a h |
Note: | For further information please see the IODD PDF file under "Downloads" |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms]: | 2.3 |
IO-Link resolution pressure [mbar]: | 1 |
IO-Link resolution pressure [MPa]: | 0.0001 |
IO-Link process data (cyclical): | function bit length pressure 14 binary switching information 1 |
function: | bit length |
pressure: | 14 |
binary switching information: | 1 |
IO-Link functions (acyclical): | application specific tag |
Profiles: | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms]: | 3 |
IO-Link resolution pressure [mbar]: | 0.5 |
IO-Link resolution pressure [MPa]: | 0.00005 |
IO-Link process data (cyclical): | function bit length pressure 16 device status 4 binary switching information 1 |
function: | bit length |
pressure: | 16 |
device status: | 4 |
binary switching information: | 1 |
IO-Link functions (acyclical): | application specific tag |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65; IP 67 |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 226 |
UL approval: | UL Approval no. J004 |
UL Approval no.: | J004 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 260 |
Materials: | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts): | stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM |
Min. pressure cycles: | 100 million |
Tightening torque [Nm]: | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection: | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Process connection sealing: | FKM (to DIN 3869) |
Restrictor element integrated: | no (can be retrofitted) |
Display: | Display unit 4 x LED, green (mbar, psi, kPa, inHg) switching status 1 x LED, yellow measured values alphanumeric display, red/green 4-digit |
Display unit: | 4 x LED, green (mbar, psi, kPa, inHg) |
switching status: | 1 x LED, yellow |
measured values: | alphanumeric display, red/green 4-digit |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.26 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |