PN3071
Pressure sensor with display. PN-250-SER14-MFRKG/US/ /V
Two switching outputs, one of them programmable as IO-Link and one as analogue output. Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Measuring range: | 0...250 bar 0...3620 psi 0...25 MPa |
| 0...250 bar: | 0...3620 psi |
| Process connection: | threaded connection G 1/4 internal thread M6 I |
| Special feature: | Gold-plated contacts |
| Measuring element: | metallic thin film cell |
| Application: | for industrial applications |
| Media: | liquids and gases |
| Medium temperature [°C]: | -25...80 |
| Min. bursting pressure: | 1200 bar 17400 psi 120 MPa |
| 1200 bar: | 17400 psi |
| Pressure rating: | 500 bar 7250 psi 50 Mpa |
| 500 bar: | 7250 psi |
| Vacuum resistance [mbar]: | -1000 |
| Type of pressure: | relative pressure |
| Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA]: | < 35 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | < 0.3 |
| Integrated watchdog: | yes |
| Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design: | PNP |
| Number of digital outputs: | 1 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Permanent current rating of switching output DC [mA]: | 150; (200 (...60 °C) 250 (...40 °C)) |
| Switching frequency DC [Hz]: | < 170 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20 |
| Max. load [Ω]: | 500 |
| Analogue voltage output [V]: | 0...10 |
| Min. load resistance [Ω]: | 2000 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | 0...250 bar 0...3620 psi 0...25 MPa |
| 0...250 bar: | 0...3620 psi |
| Set point SP: | 2...250 bar 40...3620 psi 0.2...25 MPa |
| 2...250 bar: | 40...3620 psi |
| Reset point rP: | 1...249 bar 20...3600 psi 0.1...24.9 MPa |
| 1...249 bar: | 20...3600 psi |
| Min. difference between SP and rP: | 2 bar 20 psi 0.2 MPa |
| 2 bar: | 20 psi |
| In steps of: | 1 bar 20 psi 0.1 MPa |
| 1 bar: | 20 psi |
| Set point SP: | 2...250 bar 30...3626 psi 0.2...25 MPa |
| 2...250 bar: | 30...3626 psi |
| Reset point rP: | 1...249 bar 12...3608 psi 0.1...24.9 MPa |
| 1...249 bar: | 12...3608 psi |
| Min. difference between SP and rP: | 2 bar 19 psi 0.2 MPa |
| 2 bar: | 19 psi |
| In steps of: | 1 bar 1 psi 0.1 MPa |
| 1 bar: | 1 psi |
| Switch point accuracy [% of the span]: | < ± 0,5 |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span]: | < ± 0,25 |
| Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (-25...80 °C) |
| Temperature coefficient span [% of the span / 10 K]: | 0,2; (-25...80 °C) |
| Response time [ms]: | < 3 |
| Delay time programmable dS, dr [s]: | 0...50 |
| Damping for the switching output dAP [s]: | 0...4 |
| Damping for the analogue output dAA [s]: | 0...4 |
| Max. response time analogue output [ms]: | 3 |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 1 |
| Process data binary: | 1 |
| Supported DeviceIDs: | Type of operation DeviceID Factory setting / CMPT = 2 428 d / 00 01 ac h Status_B High Resolution / CMPT = 3 607 d / 00 02 5f h |
| Type of operation: | DeviceID |
| Factory setting / CMPT = 2: | 428 d / 00 01 ac h |
| Status_B High Resolution / CMPT = 3: | 607 d / 00 02 5f h |
| Note: | For further information please see the IODD PDF file under "Downloads" |
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| Min. process cycle time [ms]: | 2.3 |
| IO-Link resolution pressure [bar]: | 1 |
| IO-Link resolution pressure [MPa]: | 0.1 |
| IO-Link process data (cyclical): | function bit length pressure 14 binary switching information 1 |
| function: | bit length |
| pressure: | 14 |
| binary switching information: | 1 |
| IO-Link functions (acyclical): | application specific tag |
| Profiles: | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
| Min. process cycle time [ms]: | 3 |
| IO-Link resolution pressure [bar]: | 0.1 |
| IO-Link resolution pressure [MPa]: | 0.01 |
| IO-Link process data (cyclical): | function bit length pressure 16 device status 4 binary switching information 1 |
| function: | bit length |
| pressure: | 16 |
| device status: | 4 |
| binary switching information: | 1 |
| IO-Link functions (acyclical): | application specific tag |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 65; IP 67 |
| EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
| Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 190 |
| UL approval: | UL Approval no. J006 |
| UL Approval no.: | J006 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 231 |
| Materials: | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L) stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts): | 1.4542 (17-4 PH / 630) |
| Min. pressure cycles: | 100 million |
| Tightening torque [Nm]: | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
| Process connection: | threaded connection G 1/4 internal thread M6 I |
| Restrictor element integrated: | no (can be retrofitted) |
| Display: | Display unit 3 x LED, green (bar, psi, MPa) switching status 1 x LED, yellow measured values alphanumeric display, red/green 4-digit |
| Display unit: | 3 x LED, green (bar, psi, MPa) |
| switching status: | 1 x LED, yellow |
| measured values: | alphanumeric display, red/green 4-digit |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.23 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |