Programmable switching output with IO-Link and scalable analogue output. Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments

Technical parameters

Output signal: switching signal; analogue signal; IO-Link; (configurable)
Measuring range: 0...600 bar 0...8700 psi 0...60 MPa
0...600 bar: 0...8700 psi
Process connection: threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5
Special feature: Gold-plated contacts
Measuring element: metallic thin film cell
Application: for industrial applications
Media: liquids and gases
Medium temperature [°C]: -25...80
Min. bursting pressure: 2500 bar 36250 psi 250 MPa
2500 bar: 36250 psi
Pressure rating: 800 bar 11580 psi 80 Mpa
800 bar: 11580 psi
Vacuum resistance [mbar]: -1000
Type of pressure: relative pressure
Operating voltage [V]: 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 35
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 0.3
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: < 500
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable 1:5)
Max. load [Ω]: 500
Analogue voltage output [V]: 0...10; (scalable 1:5)
Min. load resistance [Ω]: 2000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: 0...600 bar 0...8700 psi 0...60 MPa
0...600 bar: 0...8700 psi
Set point SP: 4...600 bar 60...8700 psi 0.4...60 MPa
4...600 bar: 60...8700 psi
Reset point rP: 1...597 bar 20...8660 psi 0.1...59.7 MPa
1...597 bar: 20...8660 psi
Analogue start point: 0...480 bar 0...6960 psi 0...48 MPa
0...480 bar: 0...6960 psi
Analogue end point: 120...600 bar 1740...8700 psi 12...60 MPa
120...600 bar: 1740...8700 psi
In steps of: 1 bar 20 psi 0.1 MPa
1 bar: 20 psi
Switch point accuracy [% of the span]: < ± 0,4; (Turn down 1:1)
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: 0,2; (-25...80 °C)
Temperature coefficient span [% of the span / 10 K]: 0,2; (-25...80 °C)
Response time [ms]: < 1.5
Delay time programmable dS, dr [s]: 0...50
Damping for the switching output dAP [s]: 0...4
Damping for the analogue output dAA [s]: 0...4
Max. response time analogue output [ms]: 3
Parameter setting options: hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 458 d / 00 01 ca h
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 65; IP 67
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 129
UL approval: UL Approval no. J014
UL Approval no.: J014
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 261.5
Materials: 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts): 1.4542 (17-4 PH / 630)
Min. pressure cycles: 100 million
Tightening torque [Nm]: 30...50; (recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connection: threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5
Process connection sealing: FKM (to DIN 3869)
Restrictor element integrated: no (can be retrofitted)
Display: Display unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit
Display unit: 3 x LED, green (bar, psi, MPa)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.26 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m