PN2060
Pressure sensor with display. PN-600-SBR14-MFRKG/US/ /V
Two switching outputs, one of them programmable as analogue output. Clearly visible 4-digit LED display. Country-specific pressure units selectable. With long-term stability thanks to high overload protection. Selectable output polarity
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Measuring range: | 0...600 bar 0...8700 psi 0...60 MPa |
| 0...600 bar: | 0...8700 psi |
| Process connection: | threaded connection G 1/4 internal thread |
| Special feature: | Gold-plated contacts |
| Application: | for industrial applications |
| Media: | liquids and gases |
| Conditionally suitable for: | use in gases at pressures > 25 bar only on request |
| Medium temperature [°C]: | -25...80 |
| Min. bursting pressure: | 1200 bar 17400 psi 120 MPa |
| 1200 bar: | 17400 psi |
| Pressure rating: | 800 bar 11600 psi 80 Mpa |
| 800 bar: | 11600 psi |
| Type of pressure: | relative pressure |
| Operating voltage [V]: | 18...32 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA]: | < 35 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 0.3 |
| Integrated watchdog: | yes |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Switching frequency DC [Hz]: | < 500 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (scalable 1:4) |
| Max. load [Ω]: | (Ub - 10 V) / 20 mA |
| Analogue voltage output [V]: | 0...10; (scalable 1:4) |
| Min. load resistance [Ω]: | 2000 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | 0...600 bar 0...8700 psi 0...60 MPa |
| 0...600 bar: | 0...8700 psi |
| Set point SP: | 6...600 bar 100...8700 psi 0.6...60 MPa |
| 6...600 bar: | 100...8700 psi |
| Reset point rP: | 2...596 bar 40...8640 psi 0.2...59.6 MPa |
| 2...596 bar: | 40...8640 psi |
| Analogue start point: | 0...450 bar 0...6520 psi 0...45 MPa |
| 0...450 bar: | 0...6520 psi |
| Analogue end point: | 150...600 bar 2120...8700 psi 15...60 MPa |
| 150...600 bar: | 2120...8700 psi |
| In steps of: | 2 bar 20 psi 0.2 MPa |
| 2 bar: | 20 psi |
| Factory setting: | SP1 = 150 bar rP1 = 138 bar SP2 = 450 bar rP2 = 438 bar ASP = 0 bar AEP = 600 bar |
| Switch point accuracy [% of the span]: | < ± 0,4; (Turn down 1:1) |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span]: | < ± 1,0; (Turn down 1:1) |
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (0...80 °C) |
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...80 °C) |
| Response time [ms]: | < 1.5 |
| Damping for the switching output dAP [s]: | 0.01...4 |
| Damping for the analogue output dAA [s]: | 0.01...4 |
| Max. response time analogue output [ms]: | 3 |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.0 |
| IO-Link device ID: | 75 d / 00 00 4B h |
| Profiles: | no profile |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 1 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 2.3 |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67 |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5/1 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 1385 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 272.5 |
| Materials: | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM |
| Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles: | 50 million |
| Process connection: | threaded connection G 1/4 internal thread |
| Restrictor element integrated: | yes |
| Display: | Display unit 3 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
| Display unit: | 3 x LED, green |
| switching status: | 2 x LED, yellow |
| function display: | alphanumeric display, 4-digit |
| measured values: | alphanumeric display, 4-digit |
| Notes: | discontinued article |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | RO |
| EAN: | |
| Weight: | 0.27 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |