PL2054
Flush pressure transmitter. PL-010-RES30-E-ZVG/US/ /P
For the reliable hydrostatic level detection. Flush mount installation in the tank or container wall. Robust potted stainless steel housing as protection against aggressive media and ingress of moisture. Scalable analogue output with adjustable span and zero point. Can be connected as two-wire or three-wire
Output signal: | analogue signal |
Measuring range: | -0.5...10 bar -7...145 psi -50...1000 kPa |
-0.5...10 bar: | -7...145 psi |
Process connection: | threaded connection Aseptoflex external thread Aseptoflex |
Special feature: | Gold-plated contacts |
Application: | food and beverage industry |
Media: | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 150 bar 2175 psi 15000 kPa |
150 bar: | 2175 psi |
Pressure rating: | 50 bar 725 psi 5000 kPa |
50 bar: | 725 psi |
Type of pressure: | relative pressure |
No dead space: | yes |
Operating voltage [V]: | 14...30 DC |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Number of inputs and outputs: | Number of analogue outputs: 1 |
Total number of outputs: | 1 |
Output signal: | analogue signal |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 550; (Ub = 24 V; (Ub - 13 V) / 20 mA) |
Overload protection: | yes |
Measuring range: | -0.5...10 bar -7...145 psi -50...1000 kPa |
-0.5...10 bar: | -7...145 psi |
Analogue start point: | -0.5...7.49 bar -7...109 psi -50...749 kPa |
-0.5...7.49 bar: | -7...109 psi |
Analogue end point: | 2...9.99 bar 29...145 psi 200...999 kPa |
2...9.99 bar: | 29...145 psi |
In steps of: | 0.01 bar 1 psi 1 kPa |
0.01 bar: | 1 psi |
Factory setting: | ASP = 0.00 bar AEP = 9.99 bar |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,6; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Linearity deviation [% of the span]: | < ± 0,5; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,1; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...80 °C) |
Max. response time analogue output [ms]: | 3 |
Parameter setting options: | zero point; span |
Communication interface: | EPS |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 271 |
Weight [g]: | 319.5 |
Materials: | stainless steel (1.4404 / 316L); PEI; FKM |
Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection Aseptoflex external thread Aseptoflex |
Remarks: | The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.32 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |