Ifm PI2795

Flush pressure sensor with display. PI-004-REA01-MFRKG/US/ /P

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Robust stainless steel housing for use in the food and beverage industry. Hygienic, flush design. Resistant to high-pressure cleaning with aggressive cleaning agents. High temperature resistance and high protection rating. Programmable analogue and switching output

Technical parameters

Output signal: switching signal; analogue signal; IO-Link; (configurable)
Measuring range: -1...4 bar -14.5...58 psi -100...400 kPa
-1...4 bar: -14.5...58 psi
Process connection: threaded connection G 1 external thread Aseptoflex Vario
Special feature: Gold-plated contacts
Application: food and beverage industry
Media: viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]: -25...125; (145 max. 1h)
Min. bursting pressure: 100 bar 1450 psi 10000 kPa
100 bar: 1450 psi
Pressure rating: 30 bar 435 psi 3000 kPa
30 bar: 435 psi
Vacuum resistance [mbar]: -1000
Type of pressure: relative pressure; vacuum
No dead space: yes
MAWP (for applications according to CRN) [bar]: 30
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Integrated watchdog: yes
Operating voltage [V]: 20...32 DC
Current consumption [mA]: 3.6...21
Power-on delay time [s]: 1
Operating voltage [V]: 18...32 DC
Current consumption [mA]: < 45
Power-on delay time [s]: 0.5
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20, invertible; (scalable)
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Max. load [Ω]: 300
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: 125
Max. load [Ω]: (Ub - 10 V) / 20 mA
Measuring range: -1...4 bar -14.5...58 psi -100...400 kPa
-1...4 bar: -14.5...58 psi
Set point SP: -0.99...4 bar -14.35...58 psi -99...400 kPa
-0.99...4 bar: -14.35...58 psi
Reset point rP: -1...3.99 bar -14.5...57.85 psi -100...399 kPa
-1...3.99 bar: -14.5...57.85 psi
Analogue start point: -1...3 bar -14.5...43.5 psi -100...300 kPa
-1...3 bar: -14.5...43.5 psi
Analogue end point: 0...4 bar 0...58 psi 0...400 kPa
0...4 bar: 0...58 psi
In steps of: 0.005 bar 0.05 psi 0.5 kPa
0.005 bar: 0.05 psi
Factory setting: SP1 = 1.000 bar rP1 = 0.920 bar SP2 = 3.000 bar rP2 = 2.920 bar ASP = 0.000 bar AEP = 4.000 bar
Switch point accuracy [% of the span]: < ± 0,2; (Turn down 1:1)
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,05; (0...70 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,15; (0...70 °C)
Damping for the switching output dAP [s]: 0...30
Damping for the analogue output dAA [s]: 0.01...99.99
Step response time analogue output [ms]: 45
Min. response time of switching output (dAP) [ms]: 3
Step response time analogue output [ms]: 7
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.0
IO-Link device ID: 158 d / 00 00 9E h
Profiles: no profile
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 67; IP 68; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-5 Surge: 0,5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 160
Note on approval: factory certificate available as download at www.factory-certificate.ifm
Weight [g]: 351.4
Materials: stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts): ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles: 100 million
Process connection: threaded connection G 1 external thread Aseptoflex Vario
Display: Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
Display unit: LED, green
switching status: LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
Display unit: bar; psi; kPa; % of the span
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.35 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m