PI2714
Flush pressure sensor with display. PI-016-REA01-MFRKG/US/ /P
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Measuring range: | -1...16 bar -14.6...232 psi -0.1...1.6 MPa |
-1...16 bar: | -14.6...232 psi |
Process connection: | threaded connection G 1 external thread Aseptoflex Vario |
Special feature: | Gold-plated contacts |
Application: | food and beverage industry |
Media: | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C]: | -25...125; (145 max. 1h) |
Min. bursting pressure: | 250 bar 3625 psi 25 MPa |
250 bar: | 3625 psi |
Pressure rating: | 75 bar 1085 psi 7.5 Mpa |
75 bar: | 1085 psi |
Vacuum resistance [mbar]: | -1000 |
Type of pressure: | relative pressure; vacuum |
No dead space: | yes |
MAWP (for applications according to CRN) [bar]: | 60 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Integrated watchdog: | yes |
Operating voltage [V]: | 20...32 DC |
Current consumption [mA]: | 3.6...21 |
Power-on delay time [s]: | 1 |
Operating voltage [V]: | 18...32 DC |
Current consumption [mA]: | < 45 |
Power-on delay time [s]: | 0.5 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20, invertible; (scalable) |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Max. load [Ω]: | 300 |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | 125 |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Measuring range: | -1...16 bar -14.6...232 psi -0.1...1.6 MPa |
-1...16 bar: | -14.6...232 psi |
Set point SP: | -0.98...16 bar -14.2...232 psi -0.098...1.6 MPa |
-0.98...16 bar: | -14.2...232 psi |
Reset point rP: | -1...15.98 bar -14.6...231.6 psi -0.1...1.598 MPa |
-1...15.98 bar: | -14.6...231.6 psi |
Analogue start point: | -1...12 bar -14.6...174 psi -0.1...1.2 MPa |
-1...12 bar: | -14.6...174 psi |
Analogue end point: | 3...16 bar 43.6...232 psi 0.3...1.6 MPa |
3...16 bar: | 43.6...232 psi |
In steps of: | 0.02 bar 0.2 psi 0.002 MPa |
0.02 bar: | 0.2 psi |
Factory setting: | SP1 = 4.0 bar rP1 = 3.68 bar SP2 = 12.0 bar rP2 = 11.68 bar ASP = 0.0 bar AEP = 16.0 bar |
Switch point accuracy [% of the span]: | < ± 0,2; (Turn down 1:1) |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Linearity deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,05; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,15; (0...70 °C) |
Damping for the switching output dAP [s]: | 0...30 |
Damping for the analogue output dAA [s]: | 0.01...99.99 |
Step response time analogue output [ms]: | 45 |
Min. response time of switching output (dAP) [ms]: | 3 |
Step response time analogue output [ms]: | 7 |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.0 |
IO-Link device ID: | 729 d / 00 02 d9 h |
Profiles: | no profile |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 1 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 2.3 |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 68; IP 69K |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5/1 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 154 |
Note on approval: | factory certificate available as download at www.factory-certificate.ifm |
Weight [g]: | 361 |
Materials: | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1 external thread Aseptoflex Vario |
Display: | Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | LED, green |
switching status: | LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Display unit: | bar; MPa; psi; % of the span |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.36 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |