PI2695
Flush pressure sensor with display. PI-004-REA01-MFRKG/US/ /P
Combined level measurement and point level detection with analogue / switching output. Resistant to high-pressure cleaning with aggressive cleaning agents. For use in high temperatures in process technology. Hygienic design for the requirements of the food and beverage industry. Flush mount installation in containers, tanks and pipes
Output signal: | switching signal; analogue signal; (configurable) |
Measuring range: | -1...4 bar -14.5...58 psi -100...400 kPa |
-1...4 bar: | -14.5...58 psi |
Process connection: | threaded connection G 1 external thread sealing cone |
Special feature: | Gold-plated contacts |
Application: | food and beverage industry |
Installation: | freely rotatable housing 350° |
Media: | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C]: | -25...125; (145 max. 1h) |
Min. bursting pressure: | 100 bar 1450 psi 10000 kPa |
100 bar: | 1450 psi |
Pressure rating: | 30 bar 435 psi 3000 kPa |
30 bar: | 435 psi |
Type of pressure: | relative pressure |
No dead space: | yes |
Operating voltage [V]: | 18...32 DC |
Current consumption [mA]: | < 50 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.5 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | 6 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20, invertible; (scalable 1:4) |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Analogue voltage output [V]: | 0...10, invertible; (scalable 1:4) |
Min. load resistance [Ω]: | 2000 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | -1...4 bar -14.5...58 psi -100...400 kPa |
-1...4 bar: | -14.5...58 psi |
Set point SP: | -0.99...4 bar -14.35...58 psi -99...400 kPa |
-0.99...4 bar: | -14.35...58 psi |
Reset point rP: | -1...3.99 bar -14.5...57.85 psi -100...399 kPa |
-1...3.99 bar: | -14.5...57.85 psi |
Analogue start point: | -1...2.75 bar -14.5...39.9 psi -100...275 kPa |
-1...2.75 bar: | -14.5...39.9 psi |
Analogue end point: | 0.25...4 bar 3.65...58 psi 25...400 kPa |
0.25...4 bar: | 3.65...58 psi |
In steps of: | 0.005 bar 0.05 psi 0.5 kPa |
0.005 bar: | 0.05 psi |
Factory setting: | SP1 = 1.000 bar rP1 = 0.920 bar ASP = 0.000 bar AEP = 4.000 bar |
Switch point accuracy [% of the span]: | < ± 0,2; (Turn down 1:1) |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Linearity deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,05; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,15; (0...70 °C) |
Response time [ms]: | < 100 |
Damping for the switching output dAP [s]: | 0.1...100 |
Damping for the analogue output dAA [s]: | 0.1...100 |
Step response time analogue output [ms]: | 25 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 69K |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5/1 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 173 |
Weight [g]: | 453.6 |
Materials: | stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1 external thread sealing cone |
Display: | Display unit 4 x LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | 4 x LED, green |
switching status: | LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Display unit: | bar; psi; kPa; % of the span |
Remarks: | The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
Notes: | discontinued article |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.45 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |