Ifm PI2694

Flush pressure sensor with display. PI-010-REA01-MFRKG/US/ /P

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Combined level measurement and point level detection with analogue / switching output. Resistant to high-pressure cleaning with aggressive cleaning agents. For use in high temperatures in process technology. Hygienic design for the requirements of the food and beverage industry. Flush mount installation in containers, tanks and pipes

Technical parameters

Output signal: switching signal; analogue signal; (configurable)
Measuring range: -1...10 bar -14.5...145 psi -0.1...1 MPa
-1...10 bar: -14.5...145 psi
Process connection: threaded connection G 1 external thread sealing cone
Special feature: Gold-plated contacts
Application: food and beverage industry
Installation: freely rotatable housing 350°
Media: viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]: -25...125; (145 max. 1h)
Min. bursting pressure: 150 bar 2175 psi 15 MPa
150 bar: 2175 psi
Pressure rating: 50 bar 725 psi 5 Mpa
50 bar: 725 psi
Type of pressure: relative pressure
No dead space: yes
Operating voltage [V]: 18...32 DC
Current consumption [mA]: < 50
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 0.5
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 1
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Number of analogue outputs: 1
Analogue current output [mA]: 4...20, invertible; (scalable 1:4)
Max. load [Ω]: (Ub - 10 V) / 20 mA
Analogue voltage output [V]: 0...10, invertible; (scalable 1:4)
Min. load resistance [Ω]: 2000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: -1...10 bar -14.5...145 psi -0.1...1 MPa
-1...10 bar: -14.5...145 psi
Set point SP: -0.98...10 bar -14.2...145 psi -0.098...1 MPa
-0.98...10 bar: -14.2...145 psi
Reset point rP: -1...9.98 bar -14.5...144.7 psi -0.1...0.998 MPa
-1...9.98 bar: -14.5...144.7 psi
Analogue start point: -1...7.25 bar -14.5...105.1 psi -0.1...0.725 MPa
-1...7.25 bar: -14.5...105.1 psi
Analogue end point: 1.75...10 bar 25.4...145 psi 0.175...1 MPa
1.75...10 bar: 25.4...145 psi
In steps of: 0.01 bar 0.1 psi 0.001 MPa
0.01 bar: 0.1 psi
Factory setting: SP1 = 2.50 bar rP1 = 2.30 bar ASP = 0.00 bar AEP = 10.00 bar
Switch point accuracy [% of the span]: < ± 0,2; (Turn down 1:1)
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,05; (0...70 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,15; (0...70 °C)
Response time [ms]: < 100
Damping for the switching output dAP [s]: 0.1...100
Damping for the analogue output dAA [s]: 0.1...100
Step response time analogue output [ms]: 25
Parameter setting options: hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 67; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-5 Surge: 0,5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 163
Weight [g]: 449.6
Materials: stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts): ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles: 100 million
Process connection: threaded connection G 1 external thread sealing cone
Display: Display unit 4 x LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
Display unit: 4 x LED, green
switching status: LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
Display unit: bar; psi; MPa; % of the span
Remarks: The 3-A qualification is only valid if adapters with 3-A qualification are used for installation.
Notes: discontinued article
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.45 kg
Length: 0.00 m
Width: 0.00 m