Ifm PI2602

Flush pressure sensor with display. PI-100-REA01-MFRKG/US/ /P

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Output signal: switching signal; analogue signal; IO-Link; (configurable)
Measuring range: -1...100 bar -15...1450 psi -0.1...10 MPa
-1...100 bar: -15...1450 psi
Process connection: threaded connection G 1 external thread sealing cone
Special feature: Gold-plated contacts
Application: food and beverage industry
Media: viscous media and liquids with suspended particles; liquids and gases
Conditionally suitable for: use in gases at pressures > 25 bar only on request
Medium temperature [°C]: -25...125; (145 max. 1h)
Min. bursting pressure: 650 bar 9425 psi 65 MPa
650 bar: 9425 psi
Pressure rating: 200 bar 2900 psi 20 Mpa
200 bar: 2900 psi
Vacuum resistance [mbar]: -1000
Type of pressure: relative pressure; vacuum
No dead space: yes
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Integrated watchdog: yes
Operating voltage [V]: 20...32 DC
Current consumption [mA]: 3.6...21
Power-on delay time [s]: 1
Operating voltage [V]: 18...32 DC
Current consumption [mA]: < 45
Power-on delay time [s]: 0.5
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20, invertible; (scalable)
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Max. load [Ω]: 300
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: 125
Max. load [Ω]: (Ub - 10 V) / 20 mA
Measuring range: -1...100 bar -15...1450 psi -0.1...10 MPa
-1...100 bar: -15...1450 psi
Set point SP: -0.8...100 bar -12...1450 psi -0.08...10 MPa
-0.8...100 bar: -12...1450 psi
Reset point rP: -1...99.8 bar -15...1448 psi -0.1...9.98 MPa
-1...99.8 bar: -15...1448 psi
Analogue start point: -1...75 bar -15...1088 psi -0.1...7.5 MPa
-1...75 bar: -15...1088 psi
Analogue end point: 24...100 bar 348...1450 psi 2.4...10 MPa
24...100 bar: 348...1450 psi
In steps of: 0.1 bar 1 psi 0.01 MPa
0.1 bar: 1 psi
Factory setting: SP1 = 25.0 bar rP1 = 23 bar SP2 = 75.0 bar rP2 = 73 bar ASP = 0.0 bar AEP = 100.0 bar
Switch point accuracy [% of the span]: < ± 0,5; (Turn down 1:1)
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,5; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,2; (0...70 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,2; (0...70 °C)
Damping for the switching output dAP [s]: 0...30
Damping for the analogue output dAA [s]: 0.01...99.99
Step response time analogue output [ms]: 45
Min. response time of switching output (dAP) [ms]: 3
Step response time analogue output [ms]: 7
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.0
IO-Link device ID: 731 d / 00 02 db h
Profiles: no profile
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 67; IP 68; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-5 Surge: 0,5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 154
Note on approval: factory certificate available as download at www.factory-certificate.ifm
Weight [g]: 374
Materials: stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts): ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles: 100 million
Process connection: threaded connection G 1 external thread sealing cone
Display: Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
Display unit: LED, green
switching status: LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
Display unit: bar; MPa; psi; % of the span
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.37 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m