PI2207
Flush pressure sensor with display. PI-001BREZ01-MFRKG/US/ /P
For use in high temperatures in the food and beverage industry. Robust stainless steel housing with hygienic front-flush design. With two-wire and three-wire connection technology. Reduced wiring complexity when operated as two-wire current loop. Integrated clamp diaphragm seal with stainless steel membrane
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Measuring range: | -50...1000 mbar -0.73...14.5 psi -5...100 kPa |
-50...1000 mbar: | -0.73...14.5 psi |
Process connection: | Clamp DN40 (1,5") DIN 32676 (ISO 2852) |
Special feature: | Gold-plated contacts |
Application: | food and beverage industry |
Media: | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C]: | -25...200 |
Min. bursting pressure: | 30000 mbar 435 psi 3000 kPa |
30000 mbar: | 435 psi |
Pressure rating: | 10000 mbar 145 psi 1000 kPa |
10000 mbar: | 145 psi |
Type of pressure: | relative pressure |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Integrated watchdog: | yes |
Operating voltage [V]: | 20...32 DC |
Current consumption [mA]: | 3.6...21 |
Power-on delay time [s]: | 1 |
Operating voltage [V]: | 18...32 DC |
Current consumption [mA]: | < 45 |
Power-on delay time [s]: | 0.5 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20, invertible; (scalable) |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Max. load [Ω]: | 300 |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | 125 |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Measuring range: | -50...1000 mbar -0.73...14.5 psi -5...100 kPa |
-50...1000 mbar: | -0.73...14.5 psi |
Set point SP: | -48...1000 mbar -0.7...14.5 psi -4.8...100 kPa |
-48...1000 mbar: | -0.7...14.5 psi |
Reset point rP: | -50...998 mbar -0.73...14.47 psi -0.5...99.8 kPa |
-50...998 mbar: | -0.73...14.47 psi |
Analogue start point: | -50...750 mbar -0.73...10.88 psi -5...75 kPa |
-50...750 mbar: | -0.73...10.88 psi |
Analogue end point: | 200...1000 mbar 2.9...14.5 psi 20...100 kPa |
200...1000 mbar: | 2.9...14.5 psi |
In steps of: | 1 mbar 0.01 psi 0.1 kPa |
1 mbar: | 0.01 psi |
Factory setting: | SP1 = 250 mbar rP1 = 230 mbar SP2 = 750 mbar rP2 = 730 mbar ASP = 0 mbar AEP = 1000 mbar |
Switch point accuracy [% of the span]: | < ± 0,2; (Turn down 1:1) |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Linearity deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,3; (0...200 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,15; (0...200 °C) |
Damping for the switching output dAP [s]: | 0...30 |
Damping for the analogue output dAA [s]: | 0.01...99.99 |
Step response time analogue output [ms]: | 45 |
Min. response time of switching output (dAP) [ms]: | 3 |
Step response time analogue output [ms]: | 7 |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.0 |
SDCI standard: | IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002 |
IO-Link device ID: | 106 d / 00 00 6A h |
Profiles: | no profile |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 1 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 2.3 |
Ambient temperature [°C]: | -25...80 |
Note on ambient temperature: | Medium temperature: ≤ 160 °C |
Ambient temperature [°C]: | -25...65 |
Note on ambient temperature: | Medium temperature: ≤ 200 °C |
Storage temperature [°C]: | -25...100 |
Protection: | IP 67; IP 68; IP 69K |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 142 |
Note on approval: | Including free 6-point calibration certificate. |
Weight [g]: | 1049.5 |
Materials: | stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA |
Materials (wetted parts): | stainless steel (1.4435 / 316L) |
Min. pressure cycles: | 10 million |
Process connection: | Clamp DN40 (1,5") DIN 32676 (ISO 2852) |
Surface characteristics Ra/Rz of the wetted parts: | < 0.38 / - |
Fill fluid for pressure transfer: | NEOBEE (food grade, FDA compliant) |
Diaphragm diameter [mm]: | 34 |
Display: | Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | LED, green |
switching status: | LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Display unit: | mbar; kPa; psi; inH2O; mWS; % of the span |
Pack quantity: | 1 pcs. |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 1.05 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |