PI009A
Pressure sensor with display. PI-1-1BREA01-MFRKG/US/3D/3G /P
For applications in hazardous areas. With switching output and analogue output. Scalable analogue output with adjustable span and zero point. Resistant to high-pressure cleaning with aggressive cleaning agents. Clearly visible 4-digit LED display
Output signal: | switching signal; analogue signal; (configurable) |
Measuring range: | -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa |
-1...1 bar: | -1000...1000 mbar |
Process connection: | threaded connection G 1 external thread sealing cone |
Special feature: | Gold-plated contacts |
Application: | food and beverage industry |
Installation: | freely rotatable housing 350° |
Media: | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C]: | -20...60; (when used outside the hazardous area:; Ambient temperature: -25...85 °C; Medium temperature: -25...125 °C / 145 °C < 1h) |
Min. bursting pressure: | 30000 mbar 435 psi 3000 kPa |
30000 mbar: | 435 psi |
Pressure rating: | 10000 mbar 145 psi 1000 kPa |
10000 mbar: | 145 psi |
Type of pressure: | relative pressure; vacuum |
Operating voltage [V]: | 18...32 DC |
Current consumption [mA]: | < 50 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.5 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | 6 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20, invertible; (scalable 1:4) |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Analogue voltage output [V]: | 0...10, invertible; (scalable 1:4) |
Min. load resistance [Ω]: | 2000 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa |
-1...1 bar: | -1000...1000 mbar |
Set point SP: | -998...1000 mbar -14.45...14.5 psi -99.8...100 kPa |
-998...1000 mbar: | -14.45...14.5 psi |
Reset point rP: | -1000...998 mbar -14.5...14.45 psi -100...99.8 kPa |
-1000...998 mbar: | -14.5...14.45 psi |
Analogue start point: | -1000...500 mbar -14.5...7.25 psi -100...50 kPa |
-1000...500 mbar: | -14.5...7.25 psi |
Analogue end point: | -500...1000 mbar -7.25...14.5 psi -50...100 kPa |
-500...1000 mbar: | -7.25...14.5 psi |
In steps of: | 1 mbar 0.05 psi 0.1 kPa |
1 mbar: | 0.05 psi |
Switch point accuracy [% of the span]: | < ± 0,2; (Turn down 1:1) |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Linearity deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,05; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,15; (0...70 °C) |
Response time [ms]: | < 100 |
Damping for the switching output dAP [s]: | 0.1...100 |
Damping for the analogue output dAA [s]: | 0.1...100 |
Step response time analogue output [ms]: | 25 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
Ambient temperature [°C]: | -20...60 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65 |
ATEX marking: | II 3D Ex tc IIIC T90°C Dc X |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5/1 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 163 |
Weight [g]: | 511.5 |
Materials: | stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE; EPDM |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1 external thread sealing cone |
Display: | Display unit 6 x, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | 6 x, green |
switching status: | LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Display unit: | mbar; kPa; psi; inH2O; mWS; % of the span |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.51 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |