Ifm PH4004

PH-010-REA01-MFRKG/US/ /P

Flush pressure sensor with analogue display. PH-010-REA01-MFRKG/US/ /P

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Analogue display, pressure switch and transmitter in one unit. Excellent readability also over a long distance. Rotatable display with LED bar graph for switch point indication. Hygienic, robust stainless steel housing for the requirements of the food and beverage industry. Flush process connection for use in CIP and SIP processes

Technical parameters

Output signal: switching signal; analogue signal; (configurable)
Measuring range: -1...10 bar -14.5...145 psi
-1...10 bar: -14.5...145 psi
Process connection: Varivent Form N, DN40 (1,5"), Ø 68 mm
Special feature: Gold-plated contacts
Application: suitable for all standard CIP and SIP processes; hygienic systems
Media: viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]: -25...125; (145 max. 1h)
Min. bursting pressure: 150 bar 2175 psi
150 bar: 2175 psi
Pressure rating: 50 bar 725 psi
50 bar: 725 psi
Type of pressure: relative pressure
Operating voltage [V]: 18...32 DC
Current consumption [mA]: 70; (24 V)
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 6
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 1
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: 50
Number of analogue outputs: 1
Analogue current output [mA]: 4...20, invertible; (scalable)
Max. load [Ω]: (Ub - 10 V) / 20 mA
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: -1...10 bar -14.5...145 psi
-1...10 bar: -14.5...145 psi
Set point SP: -0.98...16 bar -14.2...232 psi
-0.98...16 bar: -14.2...232 psi
Reset point rP: -1...15.98 bar -14.5...231.8 psi
-1...15.98 bar: -14.5...231.8 psi
Analogue start point: -1...13.5 bar -14.5...195.7 psi
-1...13.5 bar: -14.5...195.7 psi
Analogue end point [bar]: 1.5...16
In steps of: 0.01 bar 0.1 psi
0.01 bar: 0.1 psi
Switch point accuracy [% of the span]: < ± 0,2; (Turn down 1:1)
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span]: < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,05; (0...70 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,15; (0...70 °C)
Response time [ms]: < 10
Damping for the switching output dAP [s]: 0.01...30
Damping for the analogue output dAA [s]: 0.01...30
Step response time analogue output [ms]: 25
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 67; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-5 Surge: 0,5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
Weight [g]: 1020.2
Materials: stainless steel (1.4404 / 316L); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm
Materials (wetted parts): ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Min. pressure cycles: 100 million
Process connection: Varivent Form N, DN40 (1,5"), Ø 68 mm
Display: Display unit 2 x LED, green switching status LED, yellow switch points LED ring function display alphanumeric display, 4-digit measured values analogue display, 0...350° rotatable, pointer not visible when unit disconnected measured values alphanumeric display, 4-digit
Display unit: 2 x LED, green
switching status: LED, yellow
switch points: LED ring
function display: alphanumeric display, 4-digit
measured values: analogue display, 0...350° rotatable, pointer not visible when unit disconnected
measured values: alphanumeric display, 4-digit
Extended display range (max.): 16 bar 232 psi
16 bar: 232 psi
Remarks: characteristics deviation in the extended display range: 1.5 % of the span switch point accuracy in the extended display range: 1.5 % of the span
Notes: discontinued article
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DEUTSCHLAND
EAN:
Weight: 1.02 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m