PH0156
PH-2,5-RES30-E-ZVG/US/ /P
Flush pressure sensor. PH-2,5-RES30-E-ZVG/US/ /P
For the reliable hydrostatic level detection. Flush mount installation in the tank or container wall. Robust potted stainless steel housing as protection against aggressive media and ingress of moisture. Scalable analogue output with adjustable span and zero point. Can be connected as two-wire or three-wire
Output signal: | analogue signal |
Measuring range: | -0.13...2.5 bar -130...2500 mbar -1.8...36.3 psi -13...250 kPa |
-0.13...2.5 bar: | -130...2500 mbar |
Process connection: | Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Application: | food and beverage industry |
Media: | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C]: | -25...125; (145 max. 1h) |
Min. bursting pressure: | 50 bar 725 psi 5000 kPa |
50 bar: | 725 psi |
Pressure rating: | 20 bar 290 psi 2000 kPa |
20 bar: | 290 psi |
Type of pressure: | relative pressure |
No dead space: | yes |
Operating voltage [V]: | 14...30 DC |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Number of inputs and outputs: | Number of analogue outputs: 1 |
Total number of outputs: | 1 |
Output signal: | analogue signal |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 550; (Ub = 24 V; (Ub - 13 V) / 20 mA) |
Overload protection: | yes |
Measuring range: | -0.13...2.5 bar -130...2500 mbar -1.8...36.3 psi -13...250 kPa |
-0.13...2.5 bar: | -130...2500 mbar |
Analogue start point: | -0.13...1.88 bar -1.8...27.2 psi -13...188 kPa |
-0.13...1.88 bar: | -1.8...27.2 psi |
Analogue end point: | 0.5...2.5 bar 7.3...36.3 psi 50...250 kPa |
0.5...2.5 bar: | 7.3...36.3 psi |
In steps of: | 0.01 bar 0.1 psi 1 kPa |
0.01 bar: | 0.1 psi |
Factory setting: | ASP = 0.0 bar AEP = 2.50 bar |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,6; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
Linearity deviation [% of the span]: | < ± 0,5; (Turn down 1:1) |
Hysteresis deviation [% of the span]: | < ± 0,1; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...80 °C) |
Max. response time analogue output [ms]: | 3 |
Parameter setting options: | zero point; span |
Communication interface: | EPS |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
Weight [g]: | 515 |
Materials: | stainless steel (1.4404 / 316L); PEI; PBT |
Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles: | 100 million |
Process connection: | Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | DEUTSCHLAND |
EAN: | |
Weight: | 0.52 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |