Ifm PH0156

PH-2,5-RES30-E-ZVG/US/ /P

Flush pressure sensor. PH-2,5-RES30-E-ZVG/US/ /P

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

For the reliable hydrostatic level detection. Flush mount installation in the tank or container wall. Robust potted stainless steel housing as protection against aggressive media and ingress of moisture. Scalable analogue output with adjustable span and zero point. Can be connected as two-wire or three-wire

Technical parameters

Output signal: analogue signal
Measuring range: -0.13...2.5 bar -130...2500 mbar -1.8...36.3 psi -13...250 kPa
-0.13...2.5 bar: -130...2500 mbar
Process connection: Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852)
Application: food and beverage industry
Media: viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]: -25...125; (145 max. 1h)
Min. bursting pressure: 50 bar 725 psi 5000 kPa
50 bar: 725 psi
Pressure rating: 20 bar 290 psi 2000 kPa
20 bar: 290 psi
Type of pressure: relative pressure
No dead space: yes
Operating voltage [V]: 14...30 DC
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Number of inputs and outputs: Number of analogue outputs: 1
Total number of outputs: 1
Output signal: analogue signal
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 550; (Ub = 24 V; (Ub - 13 V) / 20 mA)
Overload protection: yes
Measuring range: -0.13...2.5 bar -130...2500 mbar -1.8...36.3 psi -13...250 kPa
-0.13...2.5 bar: -130...2500 mbar
Analogue start point: -0.13...1.88 bar -1.8...27.2 psi -13...188 kPa
-0.13...1.88 bar: -1.8...27.2 psi
Analogue end point: 0.5...2.5 bar 7.3...36.3 psi 50...250 kPa
0.5...2.5 bar: 7.3...36.3 psi
In steps of: 0.01 bar 0.1 psi 1 kPa
0.01 bar: 0.1 psi
Factory setting: ASP = 0.0 bar AEP = 2.50 bar
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,6; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span]: < ± 0,5; (Turn down 1:1)
Hysteresis deviation [% of the span]: < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,1; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,2; (0...80 °C)
Max. response time analogue output [ms]: 3
Parameter setting options: zero point; span
Communication interface: EPS
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 67
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
Weight [g]: 515
Materials: stainless steel (1.4404 / 316L); PEI; PBT
Materials (wetted parts): ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles: 100 million
Process connection: Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852)
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DEUTSCHLAND
EAN:
Weight: 0.52 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m