PH0104
PH-010-RES30-KFPKG/US/ /P
Flush pressure sensor. PH-010-RES30-KFPKG/US/ /P
Combined level measurement and point level detection with analogue / switching output. Resistant to high-pressure cleaning with aggressive cleaning agents. With long-term stability thanks to high repeatability and low linearity error. Hygienic design for the requirements of the food and beverage industry. Flush mount installation in containers, tanks and pipes
| Output signal: | switching signal; analogue signal; (configurable) |
| Measuring range: | -0.5...10 bar -7...145 psi -50...1000 kPa |
| -0.5...10 bar: | -7...145 psi |
| Process connection: | 1,5" |
| Special feature: | Gold-plated contacts |
| Application: | food and beverage industry |
| Installation: | freely rotatable housing 350° |
| Media: | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C]: | -25...80 |
| Min. bursting pressure: | 150 bar 2175 psi 15000 kPa |
| 150 bar: | 2175 psi |
| Pressure rating: | 50 bar 725 psi 5000 kPa |
| 50 bar: | 725 psi |
| Type of pressure: | relative pressure |
| No dead space: | yes |
| Operating voltage [V]: | 20...30 DC |
| Current consumption [mA]: | < 60 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 0.2 |
| Integrated watchdog: | yes |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Switching frequency DC [Hz]: | < 170 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (scalable 1:4) |
| Max. load [Ω]: | (Ub - 10 V) / 20 mA |
| Analogue voltage output [V]: | 0...10; (scalable 1:4) |
| Min. load resistance [Ω]: | 2000 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | -0.5...10 bar -7...145 psi -50...1000 kPa |
| -0.5...10 bar: | -7...145 psi |
| Set point SP: | -0.45...9.99 bar -7...145 psi -45...999 kPa |
| -0.45...9.99 bar: | -7...145 psi |
| Reset point rP: | -0.5...9.94 bar -7...144 psi -50...994 kPa |
| -0.5...9.94 bar: | -7...144 psi |
| Analogue start point: | -0.5...7.49 bar -7...109 psi -50...749 kPa |
| -0.5...7.49 bar: | -7...109 psi |
| Analogue end point: | 2...9.99 bar 29...145 psi 200...999 kPa |
| 2...9.99 bar: | 29...145 psi |
| In steps of: | 0.01 bar 1 psi 1 kPa |
| 0.01 bar: | 1 psi |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span]: | < ± 0,6; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
| Linearity deviation [% of the span]: | < ± 0,5; (Turn down 1:1) |
| Hysteresis deviation [% of the span]: | < ± 0,1; (Turn down 1:1) |
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1; (0...80 °C) |
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...80 °C) |
| Response time [ms]: | < 3 |
| Damping for the switching output dAP [s]: | 0...4 |
| Damping for the analogue output dAA in steps [s]: | 0 - 0,1 - 0,5 - 2 |
| Max. response time analogue output [ms]: | 3 |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67 |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| Weight [g]: | 341.5 |
| Materials: | stainless steel (1.4404 / 316L); PBT; PC; PEI; EPDM/X; FKM |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); PTFE |
| Min. pressure cycles: | 100 million |
| Process connection: | 1,5" |
| Display: | switching status 2 x LED, red function display 7-segment LED display measured values 7-segment LED display |
| switching status: | 2 x LED, red |
| function display: | 7-segment LED display |
| measured values: | 7-segment LED display |
| Display unit: | bar; psi; kPa |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | DEUTSCHLAND |
| EAN: | |
| Weight: | 0.36 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |