PG2458
Pressure sensor with analogue display. PG-,25BREB12-MFRKG/US/ /P
Analogue display, pressure switch and transmitter in one unit. Excellent readability also over a long distance. Rotatable display with LED bar graph for switch point indication. Programmable switching output and scalable analogue output. Robust stainless steel housing for use in harsh industrial environments
Output signal: | switching signal; analogue signal; (configurable) |
Measuring range: | -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O |
-0.0125...0.25 bar: | -12.5...250 mbar |
Process connection: | threaded connection G 1/2 external thread |
Special feature: | Gold-plated contacts |
Application: | for industrial applications; Safety manometer (S) based on DIN EN 837-1 |
Media: | liquids and gases |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 30000 mbar 12044 inH2O |
30000 mbar: | 12044 inH2O |
Pressure rating: | 6000 mbar 2400 inH2O |
6000 mbar: | 2400 inH2O |
Type of pressure: | relative pressure |
Operating voltage [V]: | 18...32 DC |
Current consumption [mA]: | < 70; (24 V) |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 6 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | 75 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20, invertible; (scalable) |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O |
-0.0125...0.25 bar: | -12.5...250 mbar |
Set point SP: | -11.5...400 mbar -4.6...160.6 inH2O |
-11.5...400 mbar: | -4.6...160.6 inH2O |
Reset point rP: | -12.5...399 mbar -5...160.2 inH2O |
-12.5...399 mbar: | -5...160.2 inH2O |
Analogue start point: | -12.5...337.5 mbar -5...135.6 inH2O |
-12.5...337.5 mbar: | -5...135.6 inH2O |
Analogue end point: | 50...400 mbar 20...160.6 inH2O |
50...400 mbar: | 20...160.6 inH2O |
In steps of: | 0.5 mbar 0.2 inH2O |
0.5 mbar: | 0.2 inH2O |
Switch point accuracy [% of the span]: | < ± 0,5; (Turn down 1:1) |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line) |
Hysteresis deviation [% of the span]: | < ± 0,25; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...70 °C) |
Response time [ms]: | < 9 |
Damping for the switching output dAP [s]: | 0.01...30 |
Damping for the analogue output dAA [s]: | 0.01...30 |
Step response time analogue output [ms]: | 28 |
Ambient temperature [°C]: | -20...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 69K |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5/1 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 103 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 612 |
Materials: | stainless steel (1.4404 / 316L); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm |
Materials (wetted parts): | Al2O3 (ceramics); FKM; stainless steel (1.4404 / 316L) |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1/2 external thread |
Restrictor element integrated: | no (can be retrofitted) |
Display: | Display unit 2 x LED, green switching status LED, yellow switch points LED ring, red function display alphanumeric display, red 4-digit measured values analogue display, 0...350° rotatable, pointer not visible when unit disconnected measured values alphanumeric display, red 4-digit |
Display unit: | 2 x LED, green |
switching status: | LED, yellow |
switch points: | LED ring, red |
function display: | alphanumeric display, red 4-digit |
measured values: | analogue display, 0...350° rotatable, pointer not visible when unit disconnected |
measured values: | alphanumeric display, red 4-digit |
With scale: | yes |
Extended display range (max.): | 400 mbar 160.6 inH2O |
400 mbar: | 160.6 inH2O |
Remarks: | switch point accuracy in the extended display range: 1.5 % of the span |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.61 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |