PG2454
Pressure sensor with analogue display. PG-010-REB12-MFRKG/US/ /P
Analogue display, pressure switch and transmitter in one unit. Excellent readability also over a long distance. Rotatable display with LED bar graph for switch point indication. Programmable switching output and scalable analogue output. Robust stainless steel housing for use in harsh industrial environments
Output signal: | switching signal; analogue signal; (configurable) |
Measuring range: | -1...10 bar -14.4...145 psi |
-1...10 bar: | -14.4...145 psi |
Process connection: | threaded connection G 1/2 external thread |
Special feature: | Gold-plated contacts |
Application: | for industrial applications; Safety manometer (S) based on DIN EN 837-1 |
Media: | liquids and gases |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 150 bar 2175 psi |
150 bar: | 2175 psi |
Pressure rating: | 50 bar 725 psi |
50 bar: | 725 psi |
Type of pressure: | relative pressure; vacuum |
MAWP (for applications according to CRN): | 38 bar 551 psi |
38 bar: | 551 psi |
Operating voltage [V]: | 18...32 DC |
Current consumption [mA]: | < 70; (24 V) |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 6 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | 75 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20, invertible; (scalable) |
Max. load [Ω]: | (Ub - 10 V) / 20 mA |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | -1...10 bar -14.4...145 psi |
-1...10 bar: | -14.4...145 psi |
Set point SP: | -0.96...16 bar -14...232 psi |
-0.96...16 bar: | -14...232 psi |
Reset point rP: | -1...15.96 bar -14.4...231.6 psi |
-1...15.96 bar: | -14.4...231.6 psi |
Analogue start point: | -1...13.5 bar -14.4...195.8 psi |
-1...13.5 bar: | -14.4...195.8 psi |
Analogue end point: | 1.5...16 bar 21.8...232 psi |
1.5...16 bar: | 21.8...232 psi |
In steps of: | 0.02 bar 0.2 psi |
0.02 bar: | 0.2 psi |
Switch point accuracy [% of the span]: | < ± 0,5; (Turn down 1:1) |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line) |
Hysteresis deviation [% of the span]: | < ± 0,25; (Turn down 1:1) |
Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...70 °C) |
Response time [ms]: | < 9 |
Damping for the switching output dAP [s]: | 0.01...30 |
Damping for the analogue output dAA [s]: | 0.01...30 |
Step response time analogue output [ms]: | 28 |
Ambient temperature [°C]: | -20...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 69K |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 103 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 608 |
Materials: | stainless steel (1.4404 / 316L); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm |
Materials (wetted parts): | Al2O3 (ceramics); FKM; stainless steel (1.4404 / 316L) |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1/2 external thread |
Restrictor element integrated: | no (can be retrofitted) |
Display: | Display unit 2 x LED, green switching status LED, yellow switch points LED ring, red function display alphanumeric display, red 4-digit measured values analogue display, 0...350° rotatable, pointer not visible when unit disconnected measured values alphanumeric display, red 4-digit |
Display unit: | 2 x LED, green |
switching status: | LED, yellow |
switch points: | LED ring, red |
function display: | alphanumeric display, red 4-digit |
measured values: | analogue display, 0...350° rotatable, pointer not visible when unit disconnected |
measured values: | alphanumeric display, red 4-digit |
With scale: | yes |
Extended display range (max.): | 16 bar 232 psi |
16 bar: | 232 psi |
Remarks: | switch point accuracy in the extended display range: 1.5 % of the span |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.61 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |