PE7009
Pressure sensor with display. PE-1-1BRDR14-QFRKG/US/ /E
Special seal for use in cleaning processes. Two switching outputs, one of which can be configured as diagnostic output. With long-term stability thanks to high overload protection. Clearly visible 4-digit LED display. High shock and vibration resistance
Output signal: | switching signal; IO-Link; (configurable) |
Measuring range: | -1...1 bar -1000...1000 mbar |
-1...1 bar: | -1000...1000 mbar |
Process connection: | threaded connection G 1/4 internal thread |
Special feature: | Gold-plated contacts |
Application: | for industrial applications |
Media: | liquids and gases |
Cannot be used for: | oils |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure [mbar]: | 50000 |
Pressure rating [mbar]: | 20000 |
Type of pressure: | relative pressure; vacuum |
Operating voltage [V]: | according to EN 50178 SELV/PELV |
Current consumption [mA]: | < 50 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Overvoltage protection: | yes; (< 40 V) |
Power-on delay time [s]: | 0.3 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250 |
Switching frequency DC [Hz]: | < 170 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Measuring range: | -1...1 bar -1000...1000 mbar |
-1...1 bar: | -1000...1000 mbar |
Set point SP [mbar]: | -970...1000 |
Reset point rP [mbar]: | -980...990 |
In steps of [mbar]: | 10 |
Factory setting: | SP1 = -500 mbar rP1 = -540 mbar SP2 = 500 mbar rP2 = 460 mbar |
Switch point accuracy [% of the span]: | < ± 0,5 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span]: | < ± 0,25 |
Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (-20...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | 0,2; (-20...80 °C) |
Delay time programmable dS, dr [s]: | 0; 0,2...50 |
Parameter setting options: | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
IO-Link device ID: | 314 d / 00 01 3A h |
Profiles: | no profile |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 1 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 2.3 |
Ambient temperature [°C]: | -20...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67 |
EMC: | EN 61000-6-2 EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 237 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 262 |
Materials: | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; EPDM/X; PTFE |
Materials (wetted parts): | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); sealing of the measuring cell: EPDM |
Min. pressure cycles: | 100 million |
Process connection: | threaded connection G 1/4 internal thread |
Display: | Display unit 4 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | 4 x LED, green |
switching status: | 2 x LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Display unit: | mbar; kPa; psi; inHg |
Notes: | discontinued article |
Pack quantity: | 1 pcs. |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.26 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |