Ifm PE3029

Pressure sensor with display. PE-0-1BRDR14-MFPKG/US/ /E

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Special seal for use in cleaning processes. Two switching outputs, one of which can be configured as diagnostic output. With long-term stability thanks to high overload protection. Clearly visible 4-digit LED display. High shock and vibration resistance

Technical parameters

Output signal: switching signal; analogue signal; (configurable)
Measuring range: -1...0 bar -1000...0 mbar
-1...0 bar: -1000...0 mbar
Process connection: threaded connection G 1/4 internal thread
Special feature: Gold-plated contacts
Application: for industrial applications
Media: liquids and gases
Cannot be used for: oils
Medium temperature [°C]: -25...80
Min. bursting pressure [mbar]: 30000
Pressure rating [mbar]: 10000
Type of pressure: relative pressure; vacuum
Operating voltage [V]: 18...36 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 50
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Overvoltage protection: yes; (< 40 V)
Power-on delay time [s]: 0.3
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; (configurable)
Electrical design: PNP
Number of digital outputs: 1
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: < 170
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 500
Analogue voltage output [V]: 0...10
Min. load resistance [Ω]: 2000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Measuring range: -1...0 bar -1000...0 mbar
-1...0 bar: -1000...0 mbar
Set point SP [mbar]: -990...0
Reset point rP [mbar]: -995...-5
In steps of [mbar]: 5
Factory setting: SP1 = -750 mbar rP1 = -770 mbar
Switch point accuracy [% of the span]: < ± 0,5
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,25
Long-term stability [% of the span]: < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: 0,2; (-20...80 °C)
Temperature coefficient span [% of the span / 10 K]: 0,2; (-20...80 °C)
Delay time programmable dS, dr [s]: 0; 0,2...50
Max. response time analogue output [ms]: 3
Adjustment of the switch point: programming button
Parameter setting options: hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Ambient temperature [°C]: -20...80
Storage temperature [°C]: -40...100
Protection: IP 67
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-5 Surge: 0,5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 213
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 261.5
Materials: stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; EPDM/X; PTFE
Materials (wetted parts): stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); sealing of the measuring cell: EPDM
Min. pressure cycles: 100 million
Process connection: threaded connection G 1/4 internal thread
Display: Display unit 4 x LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
Display unit: 4 x LED, green
switching status: LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
Display unit: mbar; kPa; psi; inHg
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.26 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m