PE2099
Pressure sensor with display. PE-1-1BRER14-MFRKG/US/ /E
Programmable switching output with IO-Link and scalable analogue output. Red/green display for clear identification of the acceptable range. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Measuring range: | -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa |
| -1...1 bar: | -1000...1000 mbar |
| Process connection: | threaded connection G 1/4 internal thread |
| Special feature: | Gold-plated contacts |
| Measuring element: | ceramic-capacitive pressure measuring cell |
| Application: | for industrial applications |
| Media: | liquids and gases |
| Medium temperature [°C]: | -25...80 |
| Min. bursting pressure: | 30000 mbar 435 psi 3000 kPa |
| 30000 mbar: | 435 psi |
| Pressure rating: | 10000 mbar 145 psi 1000 kPa |
| 10000 mbar: | 145 psi |
| Vacuum resistance [mbar]: | -1000 |
| Type of pressure: | relative pressure |
| Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA]: | < 35 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 0.3 |
| Integrated watchdog: | yes |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Switching frequency DC [Hz]: | < 500 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (scalable 1:5) |
| Max. load [Ω]: | 500 |
| Analogue voltage output [V]: | 0...10; (scalable 1:5) |
| Min. load resistance [Ω]: | 2000 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa |
| -1...1 bar: | -1000...1000 mbar |
| Set point SP: | -985...1000 mbar -14.3...14.5 psi -98.5...100 kPa |
| -985...1000 mbar: | -14.3...14.5 psi |
| Reset point rP: | -995...990 mbar -14.45...14.4 psi -99.5...99 kPa |
| -995...990 mbar: | -14.45...14.4 psi |
| Analogue start point: | -1000...600 mbar -14.5...8.7 psi -100...60 kPa |
| -1000...600 mbar: | -14.5...8.7 psi |
| Analogue end point: | -600...1000 mbar -8.7...14.5 psi -60...100 kPa |
| -600...1000 mbar: | -8.7...14.5 psi |
| In steps of: | 5 mbar 0.05 psi 0.5 kPa |
| 5 mbar: | 0.05 psi |
| Switch point accuracy [% of the span]: | < ± 0,4; (Turn down 1:1) |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span]: | < ± 0,1; (Turn down 1:1) |
| Long-term stability [% of the span]: | < ± 0,05; (Turn down 1:1; per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (-25...80 °C) |
| Temperature coefficient span [% of the span / 10 K]: | 0,2; (-25...80 °C) |
| Response time [ms]: | < 1.5 |
| Delay time programmable dS, dr [s]: | 0...50 |
| Damping for the switching output dAP [s]: | 0...4 |
| Damping for the analogue output dAA [s]: | 0...4 |
| Max. response time analogue output [ms]: | 3 |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| IO-Link device ID: | 467 d / 00 01 d3 h |
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 1 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 2.3 |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 65; IP 67 |
| EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
| Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 171 |
| UL approval: | UL Approval no. J012 |
| UL Approval no.: | J012 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 235 |
| Materials: | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); Al2O3 (ceramics); EPDM |
| Min. pressure cycles: | 100 million |
| Tightening torque [Nm]: | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
| Process connection: | threaded connection G 1/4 internal thread |
| Restrictor element integrated: | no (can be retrofitted) |
| Display: | Display unit 5 x LED, green (mbar, psi, kPa, inH2O, inHg) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit |
| Display unit: | 5 x LED, green (mbar, psi, kPa, inH2O, inHg) |
| switching status: | 2 x LED, yellow |
| measured values: | alphanumeric display, red/green 4-digit |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.24 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |