PC3541
PT-250-SBG14-A-ZVG/US/ /W
Pressure transmitter. PT-250-SBG14-A-ZVG/US/ /W
Precise linear 4...20 mA output signal. High repeatability and low linearity error. With long-term stability thanks to high overload protection. Robust stainless steel housing for use in harsh industrial environments. Large operating temperature range and high protection rating
| Output signal: | analogue signal |
| Measuring range [bar]: | 0...250 |
| Process connection: | threaded connection G 1/4 external thread |
| Application: | for industrial applications |
| Media: | liquids and gases |
| Medium temperature [°C]: | -25...90 |
| Min. bursting pressure [bar]: | 1000 |
| Pressure rating [bar]: | 400 |
| Type of pressure: | relative pressure |
| Operating voltage [V]: | 8.5...36 DC |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Total number of outputs: | 1 |
| Output signal: | analogue signal |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20 |
| Max. load [Ω]: | 775; (Ub = 24 V; (Ub - 8,5 V) / 20 mA) |
| Measuring range [bar]: | 0...250 |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span]: | < ± 1,0; (incl. drift when overtightened, zero point and span error) |
| Linearity deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
| Hysteresis deviation [% of the span]: | < ± 0,2 |
| Long-term stability [% of the span]: | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1; (-25...90 °C) |
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,1; (-25...90 °C) |
| Step response time analogue output [ms]: | 3 |
| Ambient temperature [°C]: | -40...90 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67; IP 69K |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 4 kV coupling clamp |
| EN 61000-4-5 Surge: | 1 kV signal for DC units |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 1579 |
| Weight [g]: | 79.2 |
| Materials: | stainless steel (1.4404 / 316L); PA |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); Sealing: FKM |
| Min. pressure cycles: | 50 million |
| Process connection: | threaded connection G 1/4 external thread |
| Remarks: | BFSL = Best Fit Straight Line LS = limit value setting |
| Notes: | discontinued article |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12 |
| ECCN: | |
| Country of Origin: | DEUTSCHLAND |
| EAN: | |
| Weight: | 0.08 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |