Ifm PC3541

PT-250-SBG14-A-ZVG/US/ /W

Pressure transmitter. PT-250-SBG14-A-ZVG/US/ /W

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise linear 4...20 mA output signal. High repeatability and low linearity error. With long-term stability thanks to high overload protection. Robust stainless steel housing for use in harsh industrial environments. Large operating temperature range and high protection rating

Technical parameters

Output signal: analogue signal
Measuring range [bar]: 0...250
Process connection: threaded connection G 1/4 external thread
Application: for industrial applications
Media: liquids and gases
Medium temperature [°C]: -25...90
Min. bursting pressure [bar]: 1000
Pressure rating [bar]: 400
Type of pressure: relative pressure
Operating voltage [V]: 8.5...36 DC
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Number of inputs and outputs: Number of analogue outputs: 1
Total number of outputs: 1
Output signal: analogue signal
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 775; (Ub = 24 V; (Ub - 8,5 V) / 20 mA)
Measuring range [bar]: 0...250
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 1,0; (incl. drift when overtightened, zero point and span error)
Linearity deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS)
Hysteresis deviation [% of the span]: < ± 0,2
Long-term stability [% of the span]: < ± 0,1; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,1; (-25...90 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,1; (-25...90 °C)
Step response time analogue output [ms]: 3
Ambient temperature [°C]: -40...90
Storage temperature [°C]: -40...100
Protection: IP 67; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 4 kV coupling clamp
EN 61000-4-5 Surge: 1 kV signal for DC units
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 1579
Weight [g]: 79.2
Materials: stainless steel (1.4404 / 316L); PA
Materials (wetted parts): stainless steel (1.4404 / 316L); Sealing: FKM
Min. pressure cycles: 50 million
Process connection: threaded connection G 1/4 external thread
Remarks: BFSL = Best Fit Straight Line LS = limit value setting
Notes: discontinued article
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DEUTSCHLAND
EAN:
Weight: 0.08 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m