Ifm OGD582

Photoelectric distance sensor. OGDLFPKG/IO-LINK/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Simultaneous output of distance value and reflectivity for increased process reliability. Identification and sorting by differentiating between colour/contrast and distance/height of objects. Flexible installation options thanks to a range of up to 1.5 m

Technical parameters

Type of light: red light
Setting range distance [m]: 0.085...1.5
Setting range object reflectivity [%]: 6...900; (reflectivity; 6 % black paper; 100 % white paper)
Communication interface: IO-Link
Laser protection class: 1
Dimensions [mm]: 61.7 x 22.5 x 45.2
Operating voltage [V]: 10...30 DC; ("supply class 2" to cULus)
Current consumption [mA]: < 75
Current consumption reference voltage [V]: 24
Protection class: III
Reverse polarity protection: yes
Type of light: red light
Wave length [nm]: 650
Typ. lifetime [h]: 50000
Inputs: Laser On/ Off
Electrical design: PNP
Output function: 2 x normally open / normally closed; (parameterisable)
Max. current load per output [mA]: 100
Type of short-circuit protection: pulsed
Overload protection: yes
Max. light spot diameter [mm]: 5
Light spot dimensions refer to: at maximum range
Background suppression [m]: < 20
Setting range distance [m]: 0.085...1.5
Setting range object reflectivity [%]: 6...900; (reflectivity; 6 % black paper; 100 % white paper)
Sampling rate [Hz]: 33
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 926d / 00039Eh
Profiles: Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode: yes
Required master port type: A
Min. process cycle time [ms]: 5
IO-Link process data (cyclical): function bit length process value 2 x 16 device status 4 binary switching information 2
function: bit length
process value: 2 x 16
device status: 4
binary switching information: 2
IO-Link functions (acyclical): application specific tag; operating hours counter; switching cycles counter
Note: For further information please see the IODD PDF file under "Downloads"
Ambient temperature [°C]: -25...60
Note on ambient temperature: In ambient temperatures < -10 °C a warm-up time is necessary. Laser is off.
Storage temperature [°C]: -30...80
Protection: IP 65; IP 67
Laser protection class: 1
Notes on laser protection: Caution: laser light laser class: 1 EN / IEC60825-1:2007 EN / IEC60825-1:2014 Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
Caution:: laser light
laser class:: 1
MTTF [years]: 217
UL approval: Ta -25...60 °C Enclosure type Type 1 voltage supply Class 2 File number UL E174191
Ta: -25...60 °C
Enclosure type: Type 1
voltage supply: Class 2
File number UL: E174191
Weight [K40]: 229.8
Dimensions [mm]: 61.7 x 22.5 x 45.2
Materials: Housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT / PC; EPDM; front lens: glass
Display: switching status 2 x LED, yellow 1 x alphanumeric display, 3-digit
switching status: 2 x LED, yellow
Operating elements: 3 pushbutton
3: pushbutton
Accessories (supplied): lock nuts: 2
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12
Parameter: Setting range
Uni: cm
OU1: Hno, Hnc, Fno, Fnc, OFF
SP1 [cm]: 8.5…150
nP1 [cm]: 8.5…150
FP1 [cm]: 8.5…150
LG1: And,Or,Off
dS1 [s]: 0…0.1…5
dr1 [s]: 0…0.1…5
OU2: Hno, Hnc, Fno, Fnc, OFF
SP2 [%]: 6…900
bP2 [%]: 6…900
dP2 [%]: 6…900
HyL: Lo/Hi
LG2: And,Or,Off
dS2 [s]: 0...0.1...5
dr2 [s]: 0...0.1...5
dFO [s]: 0...0.1...5
dIS: ON / OFF
distance: white (90 % remission)
85 mm: 8.0 mm
750 mm: 8.0 mm
1500 mm: 20.0 mm
Extraneous light on the object: < 10 klx
constant ambient conditions: 23 °C / 960 hPa
minimum power-on time in minutes: 10

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.23 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m