O3D223
3D camera. O3DIRP3KG/E1/E2/GM/W/64
Visual assessment of distance, level or volume. Reliable distance measurement due to time-of-flight measurement. Illumination, measurement and evaluation in one unit. Output of 3072 distance and grey values per measurement for a detailed evaluation of the application. Integration by means of intuitive parameter setting software
| Image resolution 3D [px]: | 64 x 48 |
| Angle of aperture 3D [°]: | 64 x 48 |
| Max. reading rate [Hz]: | 20 |
| Communication interface: | Ethernet |
| Dimensions [mm]: | 123.5 x 75 x 95 |
| Application: | output of 3D image data |
| Operating voltage [V]: | 20.4...28.8 DC; (EN 61131-2) |
| Current consumption [mA]: | < 2000; (peak current pulsed; typical value: 600) |
| Power consumption [W]: | 15 |
| Protection class: | III |
| Image sensor: | PMD 3D ToF-Chip |
| Internal lighting: | yes; (infrared: 850 nm invisible radiation LED class 1) |
| Number of inputs and outputs: | Number of digital inputs: 2; Number of digital outputs: 2 |
| Number of digital inputs: | 2 |
| Trigger: | 24 V PNP (IEC 61131-2 Typ 1) |
| Input circuit of digital inputs: | 24 V PNP; (configurable; IEC 61131-2 Typ 1) |
| Total number of outputs: | 2 |
| Number of digital outputs: | 2; (configurable) |
| Output function: | 24 V PNP; (EN 61131-2 Typ 2) |
| Max. voltage drop switching output DC [V]: | 1 |
| Max. current load per output [mA]: | 100 |
| Analogue current output [mA]: | 4...20 |
| Max. load [Ω]: | 300 |
| Analogue voltage output [V]: | 0...10 |
| Min. load resistance [Ω]: | 10000 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Operating distance [mm]: | 200...5500 |
| Note on operating distance: | white paper: 200 x 200 mm reflectivity: 90 % |
| Image resolution 3D [px]: | 64 x 48 |
| Angle of aperture 3D [°]: | 64 x 48 |
| Max. reading rate [Hz]: | 20 |
| Parameter setting options: | via two pushbuttons and 10-segment display or via PC / notebook with operating software |
| Communication interface: | Ethernet |
| Number of Ethernet interfaces: | 1 |
| Transmission standard: | 10Base-T; 100Base-TX |
| Transmission rate: | 10; 100 |
| Protocol: | TCP/IP; EtherNet/IP |
| Factory settings: | IP address: 192.168.0.69 subnet mask: 255.255.255.0 gateway IP address: 192.168.0.201 MAC address: see type label |
| Ambient temperature [°C]: | -10...50 |
| Storage temperature [°C]: | -40...85 |
| Protection: | IP 67 |
| Max. immunity to extraneous light [klx]: | 8; (on the object) |
| EMC: | EN 61000-6-4 radiation of interference / industrial environments EN 61000-6-2 immunity / industrial environments |
| EN 61000-6-4: | radiation of interference / industrial environments |
| EN 61000-6-2: | immunity / industrial environments |
| Shock resistance: | DIN EN 60068-2-27 30 g 11 ms |
| DIN EN 60068-2-27: | 30 g 11 ms |
| Vibration resistance: | DIN EN 60068-2-6 2 g 10...150 Hz |
| DIN EN 60068-2-6: | 2 g 10...150 Hz |
| Photobiological safety: | exempt group; (DIN EN 62471) |
| Electrical protection: | EN 61131-2 electrical supply only via PELV circuits |
| EN 61131-2: | electrical supply only via PELV circuits |
| Weight [K40]: | 1197.5 |
| Dimensions [mm]: | 123.5 x 75 x 95 |
| Materials: | housing: diecast aluminium; front lens: PMMA; display window: PC |
| Display: | switching status 4 x LED, yellow 4 x LED, green 10-segment display, 4-digit |
| switching status: | 4 x LED, yellow |
| Accessories (supplied): | Protective covers |
| Notes: | For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
| Pack quantity: | 1 pcs. |
| measuring range / distance: | Length |
| 200: | 250 |
| 1000: | 1260 |
| 2000: | 2520 |
| 3000: | 3780 |
| 4000: | 5040 |
| 5500: | 6930 |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 1.20 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |