O3D222
3D sensor. O3DIRP3KG/E1/E2/GM/W/64
Visual assessment of distance, level or volume. Reliable distance measurement due to time-of-flight measurement. Illumination, measurement and evaluation in one unit. 3,072 distance values per measurement for the detailed assessment of the application. Two switching outputs, one of them programmable as analogue output
Image resolution 3D [px]: | 64 x 48 |
Angle of aperture 3D [°]: | 64 x 48 |
Max. reading rate [Hz]: | 20 |
Communication interface: | Ethernet |
Dimensions [mm]: | 123.5 x 75 x 95 |
Application: | Level monitoring; distance monitoring; volume monitoring |
Operating voltage [V]: | 20.4...28.8 DC; (EN 61131-2) |
Current consumption [mA]: | < 2000; (peak current pulsed; typical value: 600) |
Power consumption [W]: | 15 |
Protection class: | III |
Image sensor: | PMD 3D ToF-Chip |
Internal lighting: | yes; (infrared: 850 nm invisible radiation LED class 1) |
Number of inputs and outputs: | Number of digital inputs: 2; Number of digital outputs: 2 |
Number of digital inputs: | 2 |
Trigger: | 24 V PNP (IEC 61131-2 Typ 1) |
Input circuit of digital inputs: | 24 V PNP; (configurable; IEC 61131-2 Typ 1) |
Total number of outputs: | 2 |
Number of digital outputs: | 2; (configurable) |
Output function: | 24 V PNP; (EN 61131-2 Typ 2) |
Max. voltage drop switching output DC [V]: | 1 |
Max. current load per output [mA]: | 100 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 300 |
Analogue voltage output [V]: | 0...10 |
Min. load resistance [Ω]: | 10000 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Operating distance [mm]: | 200...5500 |
Note on operating distance: | white paper: 200 x 200 mm reflectivity: 90 % |
Image resolution 3D [px]: | 64 x 48 |
Angle of aperture 3D [°]: | 64 x 48 |
Max. reading rate [Hz]: | 20 |
Parameter setting options: | via two pushbuttons and 10-segment display or via PC / notebook with operating software |
Communication interface: | Ethernet |
Number of Ethernet interfaces: | 1 |
Transmission standard: | 10Base-T; 100Base-TX |
Transmission rate: | 10; 100 |
Protocol: | TCP/IP; EtherNet/IP |
Factory settings: | IP address: 192.168.0.69 subnet mask: 255.255.255.0 gateway IP address: 192.168.0.201 MAC address: see type label |
Ambient temperature [°C]: | -10...50 |
Storage temperature [°C]: | -40...85 |
Protection: | IP 67 |
Max. immunity to extraneous light [klx]: | 8; (on the object) |
EMC: | EN 61000-6-4 radiation of interference / industrial environments EN 61000-6-2 immunity / industrial environments |
EN 61000-6-4: | radiation of interference / industrial environments |
EN 61000-6-2: | immunity / industrial environments |
Shock resistance: | DIN EN 60068-2-27 30 g 11 ms |
DIN EN 60068-2-27: | 30 g 11 ms |
Vibration resistance: | DIN EN 60068-2-6 2 g 10...150 Hz |
DIN EN 60068-2-6: | 2 g 10...150 Hz |
Photobiological safety: | exempt group; (DIN EN 62471) |
Electrical protection: | EN 61131-2 electrical supply only via PELV circuits |
EN 61131-2: | electrical supply only via PELV circuits |
Weight [K40]: | 1200 |
Dimensions [mm]: | 123.5 x 75 x 95 |
Materials: | housing: diecast aluminium; front lens: PMMA; display window: PC |
Display: | switching status 4 x LED, yellow 4 x LED, green 10-segment display, 4-digit |
switching status: | 4 x LED, yellow |
Accessories (supplied): | Protective covers |
Notes: | For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
Pack quantity: | 1 pcs. |
measuring range / distance: | Length |
200: | 250 |
1000: | 1260 |
2000: | 2520 |
3000: | 3780 |
4000: | 5040 |
5500: | 6930 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 1.20 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |