Ifm O1D155

Photoelectric distance sensor. O1DLF3KG/IO-LINK

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Reliable optical distance measurement with high ranges up to 6 m. Two switching outputs, one of them programmable as analogue output. Scalable measuring range and window function. Laser protection class 1 for the requirements of the automotive industry. Excellent price/performance ratio

Technical parameters

Type of light: red light
Communication interface: IO-Link
Laser protection class: 1
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 150
Protection class: III
Reverse polarity protection: yes
Type of light: red light
Wave length [nm]: 650
Typ. lifetime [h]: 50000
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (programmable)
Max. current load per output [mA]: 200
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (IEC 61131-2)
Max. load [Ω]: 250
Analogue voltage output [V]: 0...10; (IEC 61131-2)
Min. load resistance [Ω]: 5000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Max. light spot width [mm]: 8
Max. light spot height [mm]: 8
Light spot dimensions refer to: 6 m
Background suppression [m]: 6...100
Measuring range [m]: 0.3...6; (white paper 200 x 200 mm 90% remission)
Sampling rate [Hz]: 1...33
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 812 d / 00 03 2 Ch
Profiles: Smart Sensor: Sensor Identification; Binary Data Channel, Process Value; Sensor Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 2
Process data binary: 2
Min. process cycle time [ms]: 6
Ambient temperature [°C]: -10...60
Protection: IP 67
EMC: EN 60947-5-2
Laser protection class: 1
Notes on laser protection: Caution: laser light laser class: 1 EN / IEC60825-1:2007 EN / IEC60825-1:2014 Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
Caution:: laser light
laser class:: 1
MTTF [years]: 186
Weight [K40]: 310.5
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Materials: housing: diecast zinc; front lens: glass; LED window: PC
Display: switching status 2 x LED, yellow operation LED, green distance value, programming alphanumeric display, 4-digit
switching status: 2 x LED, yellow
operation: LED, green
distance value, programming: alphanumeric display, 4-digit
Accessories (optional): Protective cover, E21133
Remarks: operating voltage "supply class 2" according to cULus
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12
Parameter: Setting range
Uni: mm, m, inch
OU1: Hno, Hnc, Fno, Fnc
SP1: 300...5999
nSP1: 300...5999
FSP1: 300...5999
OU2: Hno, Hnc, Fno, Fnc, I, U
SP2: 300...5999
nSP2: 300...5999
FSP2: 300...5999
ASP: 0...5999
AEP: 0...5999
rATE [Hz]: 1...33
dS1: 0...0.1...5
dr1: 0...0.1...5
dS2: 0...0.1...5
dr2: 0...0.1...5
dFo: 0...0.1...5
dIS: d1...3 ; rd1...3; OFF
300...1000 mm: ± 11 mm
1000...2000 mm: ± 28 mm
2000...3000 mm: ± 50 mm
3000...4000 mm: ± 85 mm
4000...5000 mm: ± 105 mm
5000...6000 mm: ± 145 mm
Sampling rate: 15 Hz
300...1000 mm: ± 8 mm
1000...2000 mm: ± 25 mm
2000...3000 mm: ± 38 mm
3000...4000 mm: ± 70 mm
4000...5000 mm: ± 100 mm
5000...6000 mm: ± 100 mm
Sampling rate: 1 Hz
Range on black object (6 % remission): <= 2500 klx
Extraneous light on the object: < 100 klx
constant ambient conditions: 23 °C / 960 hPa
minimum power-on time in minutes: 10

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.31 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m