O1D120
Photoelectric distance sensor. O1DLF3KG/IO-LINK
Reliable optical distance measurement with high ranges up to 10 m. Two switching outputs, one of them programmable as IO-Link and one as analogue output. Scalable measuring range and window function. Use in applications with background suppression. Excellent price/performance ratio
| Communication interface: | IO-Link |
| Laser protection class: | 2 |
| Housing: | rectangular |
| Dimensions [mm]: | 59 x 42 x 52 |
| Special feature: | Background suppression |
| Operating voltage [V]: | 18...30 DC |
| Current consumption [mA]: | < 150 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Typ. lifetime [h]: | 50000 |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Electrical design: | PNP |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (programmable) |
| Max. current load per output [mA]: | 200 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20 |
| Max. load [Ω]: | 250 |
| Analogue voltage output [V]: | 0...10 |
| Min. load resistance [Ω]: | 5000 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Max. light spot width [mm]: | 15 |
| Max. light spot height [mm]: | 15 |
| Light spot dimensions refer to: | 10 m |
| Background suppression available: | yes |
| Background suppression [m]: | 0...19 |
| Measuring range [m]: | 0.2...10; (white paper 200 x 200 mm 90% remission) |
| Sampling rate [Hz]: | 1...50 |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| IO-Link device ID: | 806 d / 00 03 26 h |
| Profiles: | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 2 |
| Process data binary: | 3 |
| Min. process cycle time [ms]: | 6 |
| Ambient temperature [°C]: | -10...60 |
| Protection: | IP 67 |
| EMC: | EN 60947-5-2 |
| Laser protection class: | 2 |
| Notes on laser protection: | Caution: laser light Power: <= 4,0 mW Wave length: 650 nm pulse: 1,3 ns Do not stare into beam. Avoid exposure to the laser light. laser class: 2 EN / IEC60825-1:2007 EN / IEC60825-1:2014 Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
| Caution:: | laser light |
| Power:: | <= 4,0 mW |
| Wave length:: | 650 nm |
| pulse:: | 1,3 ns |
| laser class:: | 2 |
| Weight [K40]: | 314 |
| Housing: | rectangular |
| Dimensions [mm]: | 59 x 42 x 52 |
| Materials: | housing: diecast zinc; front lens: glass; LED window: PC |
| Lens alignment: | side lens |
| Display: | switching status 2 x LED, yellow operation LED, green distance value, programming alphanumeric display, 4-digit |
| switching status: | 2 x LED, yellow |
| operation: | LED, green |
| distance value, programming: | alphanumeric display, 4-digit |
| Accessories (optional): | Protective cover, E21133 |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12 |
| Parameter: | Setting range |
| Uni: | mm, m, inch |
| OU1: | Hno, Hnc, Fno, Fnc |
| SP1 [mm]: | 200...9999 |
| nSP1 [mm]: | 200...9999 |
| FSP1 [mm]: | 200...9999 |
| OU2: | Hno, Hnc, Fno, Fnc, I, U |
| SP2 [mm]: | 200...9999 |
| nSP2 [mm]: | 200...9999 |
| FSP2 [mm]: | 200...9999 |
| ASP [mm]: | 0...9999 |
| AEP [mm]: | 0...9999 |
| rATE [Hz]: | 1...50 |
| dS1 [s]: | 0...0.1...5 |
| dr1 [s]: | 0...0.1...5 |
| dS2 [s]: | 0...0.1...5 |
| dr2 [s]: | 0...0.1...5 |
| dFo [s]: | 0...0.1...5 |
| dIS: | d1...3 ; rd1...3; OFF |
| read/write distance (mm): | repeatability of the measured values |
| 200...1000 mm: | ± 5.0 mm |
| 1000...2000 mm: | ± 5.5 mm |
| 2000...4000 mm: | ± 17.5 mm |
| 4000...6000 mm: | ± 27.5 mm |
| 6000...10000 mm: | ± 60.0 mm |
| Sampling rate: | 50 Hz |
| Extraneous light on the object: | < 40 klx |
| read/write distance (mm): | repeatability of the measured values |
| 200...1000 mm: | ± 16.5 mm |
| 1000...2000 mm: | ± 16.5 mm |
| 2000...4000 mm: | ± 30.0 mm |
| 4000...6000 mm: | ± 37.0 mm |
| 6000...10000 mm: | ± 75.0 mm |
| Sampling rate: | 50 Hz |
| Extraneous light on the object: | 40...100 klx |
| read/write distance (mm): | repeatability of the measured values |
| 200...1000 mm: | ± 4.0 mm |
| 1000...2000 mm: | ± 4.5 mm |
| 2000...4000 mm: | ± 13.5 mm |
| 4000...6000 mm: | ± 19.0 mm |
| 6000...10000 mm: | ± 37.0 mm |
| Sampling rate: | 1 Hz |
| Extraneous light on the object: | < 40 klx |
| read/write distance (mm): | repeatability of the measured values |
| 200...1000 mm: | ± 10.0 mm |
| 1000...2000 mm: | ± 10.0 mm |
| 2000...4000 mm: | ± 17.0 mm |
| 4000...6000 mm: | ± 22.0 mm |
| 6000...10000 mm: | ± 37.0 mm |
| Range on black object (6 % remission): | <= 4000 mm |
| Extraneous light on the object: | < 40...100 klx |
| constant ambient conditions: | 23 °C / 960 hPa |
| minimum power-on time in minutes: | 10 |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.31 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |