Ifm O1D120

Photoelectric distance sensor. O1DLF3KG/IO-LINK

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Reliable optical distance measurement with high ranges up to 10 m. Two switching outputs, one of them programmable as IO-Link and one as analogue output. Scalable measuring range and window function. Use in applications with background suppression. Excellent price/performance ratio

Technical parameters

Communication interface: IO-Link
Laser protection class: 2
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Special feature: Background suppression
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 150
Protection class: III
Reverse polarity protection: yes
Typ. lifetime [h]: 50000
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (programmable)
Max. current load per output [mA]: 200
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 250
Analogue voltage output [V]: 0...10
Min. load resistance [Ω]: 5000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Max. light spot width [mm]: 15
Max. light spot height [mm]: 15
Light spot dimensions refer to: 10 m
Background suppression available: yes
Background suppression [m]: 0...19
Measuring range [m]: 0.2...10; (white paper 200 x 200 mm 90% remission)
Sampling rate [Hz]: 1...50
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 806 d / 00 03 26 h
Profiles: Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 2
Process data binary: 3
Min. process cycle time [ms]: 6
Ambient temperature [°C]: -10...60
Protection: IP 67
EMC: EN 60947-5-2
Laser protection class: 2
Notes on laser protection: Caution: laser light Power: <= 4,0 mW Wave length: 650 nm pulse: 1,3 ns Do not stare into beam. Avoid exposure to the laser light. laser class: 2 EN / IEC60825-1:2007 EN / IEC60825-1:2014 Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
Caution:: laser light
Power:: <= 4,0 mW
Wave length:: 650 nm
pulse:: 1,3 ns
laser class:: 2
Weight [K40]: 314
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Materials: housing: diecast zinc; front lens: glass; LED window: PC
Lens alignment: side lens
Display: switching status 2 x LED, yellow operation LED, green distance value, programming alphanumeric display, 4-digit
switching status: 2 x LED, yellow
operation: LED, green
distance value, programming: alphanumeric display, 4-digit
Accessories (optional): Protective cover, E21133
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12
Parameter: Setting range
Uni: mm, m, inch
OU1: Hno, Hnc, Fno, Fnc
SP1 [mm]: 200...9999
nSP1 [mm]: 200...9999
FSP1 [mm]: 200...9999
OU2: Hno, Hnc, Fno, Fnc, I, U
SP2 [mm]: 200...9999
nSP2 [mm]: 200...9999
FSP2 [mm]: 200...9999
ASP [mm]: 0...9999
AEP [mm]: 0...9999
rATE [Hz]: 1...50
dS1 [s]: 0...0.1...5
dr1 [s]: 0...0.1...5
dS2 [s]: 0...0.1...5
dr2 [s]: 0...0.1...5
dFo [s]: 0...0.1...5
dIS: d1...3 ; rd1...3; OFF
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 5.0 mm
1000...2000 mm: ± 5.5 mm
2000...4000 mm: ± 17.5 mm
4000...6000 mm: ± 27.5 mm
6000...10000 mm: ± 60.0 mm
Sampling rate: 50 Hz
Extraneous light on the object: < 40 klx
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 16.5 mm
1000...2000 mm: ± 16.5 mm
2000...4000 mm: ± 30.0 mm
4000...6000 mm: ± 37.0 mm
6000...10000 mm: ± 75.0 mm
Sampling rate: 50 Hz
Extraneous light on the object: 40...100 klx
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 4.0 mm
1000...2000 mm: ± 4.5 mm
2000...4000 mm: ± 13.5 mm
4000...6000 mm: ± 19.0 mm
6000...10000 mm: ± 37.0 mm
Sampling rate: 1 Hz
Extraneous light on the object: < 40 klx
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 10.0 mm
1000...2000 mm: ± 10.0 mm
2000...4000 mm: ± 17.0 mm
4000...6000 mm: ± 22.0 mm
6000...10000 mm: ± 37.0 mm
Range on black object (6 % remission): <= 4000 mm
Extraneous light on the object: < 40...100 klx
constant ambient conditions: 23 °C / 960 hPa
minimum power-on time in minutes: 10

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.31 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m