Ifm O1D106

Photoelectric distance sensor. O1DLF3KG

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Reliable optical distance measurement. Range up to 75 m for use on cranes. Two switching outputs, one of them programmable as analogue output. Excellent price/performance ratio. Wide range of components for quick mounting and precise fine adjustment

Technical parameters

Communication interface: IO-Link
Laser protection class: 2
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 150
Protection class: III
Reverse polarity protection: yes
Typ. lifetime [h]: 50000
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (programmable)
Max. current load per output [mA]: 200
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable IEC 61131-2)
Max. load [Ω]: 250
Analogue voltage output [V]: 0...10; (scalable IEC 61131-2)
Min. load resistance [Ω]: 5000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Max. light spot width [mm]: 150
Max. light spot height [mm]: 150
Light spot dimensions refer to: 75 m
Background suppression [m]: 75...150
Measuring range [m]: 1...75; (Reflector E21159)
Sampling rate [Hz]: 1...33
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 810d / 00 03 2Ah
Profiles: Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 6
Ambient temperature [°C]: -10...60
Protection: IP 67
EMC: EN 60947-5-2
Laser protection class: 2
Notes on laser protection: Caution: laser light Power: <= 4,0 mW Wave length: 650 nm pulse: 1,3 ns Do not stare into beam. Avoid exposure to the laser light. laser class: 2 EN / IEC60825-1:2007 EN / IEC60825-1:2014 Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
Caution:: laser light
Power:: <= 4,0 mW
Wave length:: 650 nm
pulse:: 1,3 ns
laser class:: 2
MTTF [years]: 106
Weight [K40]: 312
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Materials: housing: diecast zinc; front lens: glass; LED window: PC
Lens alignment: side lens
Display: switching status 2 x LED, yellow operation LED, green distance value, programming alphanumeric display, 4-digit
switching status: 2 x LED, yellow
operation: LED, green
distance value, programming: alphanumeric display, 4-digit
Remarks: operating voltage "supply class 2" according to cULus
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12
Parameter: Setting range
Uni: m, feet
OU1: Hno, Hnc, Fno, Fnc
SP1: 1.00...75.00
nSP1: 1.00...75.00
FSP1: 1.00...75.00
OU2: Hno, Hnc, Fno, Fnc, I, U
SP2: 1.00...75.00
nSP2: 1.00...75.00
FSP2: 1.00...75.00
ASP: 0...75.00
AEP: 0...75.00
rATE [Hz]: 1...33
dS1: 0...0.1...5
dr1: 0...0.1...5
dS2: 0...0.1...5
dr2: 0...0.1...5
dFo: 0...0.1...5
dIS: d1...3; rd1...3; OFF
1...25 m: ± 15 mm
30 m: ± 15 mm
40 m: ± 15 mm
50 m: ± 19 mm
60 m: ± 27 mm
70 m: ± 43 mm
Reflector: 33 Hz
1...75 m: ± 15 mm
Reflector: 1 Hz
Extraneous light on the object: < 100 klx
constant ambient conditions: 23 °C / 960 hPa
minimum power-on time in minutes: 10

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.31 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m