Ifm MN200S

Magnetically coded sensor. MN14005-AKOG/-H

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Actuation possible from different directions. Conceal behind stainless steel for enhanced tamper prevention. Meets the new interface description CB24I from ZVEI. Meets highest safety levels to ISO 13849-1 and SILCL 3 to IEC 62061

Technical parameters

Output function: 2 x normally open
Sensing range [mm]: 5; (with defined actuator)
Housing: rectangular
Dimensions [mm]: 36 x 13 x 26
Design: coded target
Type of operation: permanent operation
Operating voltage [V]: 24 DC
Rated insulation voltage [V]: 60
Protection class: III
Reverse polarity protection: no
Internal resistance (Ri) [Ω]: 10; (1 W)
Output function: 2 x normally open
Permanent current rating of switching output DC [mA]: 50
Switching frequency DC [Hz]: 150
Output data: Interface type A
Short-circuit proof: no
Max. capacitive load CL_max [nF]: 20
Sensing range [mm]: 5; (with defined actuator)
Safe switching-off distance s(ar) [mm]: 15
Response time to safety request [ms]: 10
Max. fall time [ms]: 0.1
Max. make time incl. bounce [ms]: 0.6
Applications: class C to EN 60654-1 weatherproof application
Ambient temperature [°C]: -25...80
Note on ambient temperature: operational life ≤ 87600 h
Ambient temperature [°C]: 10...40
Note on ambient temperature: operational life ≤ 175200 h
Max. relative air humidity [%]: briefly: 5...95 %; permanent: 5...70 %
Air pressure [kPa]: 80...106
Max. height above sea level [m]: 2000
Salt spray: no
Protection: IP 67; IP 69K; (protected cable laying)
EMC: IEC 60947-5-1
Shock resistance: EN 60068-2-27 30 g (11 ms)
EN 60068-2-27: 30 g (11 ms)
Vibration resistance: IEC 60068-2-6 10 g (10...55 Hz)
IEC 60068-2-6: 10 g (10...55 Hz)
Mission time TM [h]: ≤ 175200
Mission time TM (additional indication): 20 years
B10D: 20.000.000; (without load; at max. load DC 12, 24 V, 50 mA : 400.000)
Weight [g]: 187
Housing: rectangular
Mounting: non-flush mountable
Dimensions [mm]: 36 x 13 x 26
Materials: PA
Tightening torque [Nm]: 0.8...2
Accessories (supplied): coded target cover caps : 4
Remarks: In connection with a G150xS / AC4x2S type evaluation unit, it is possible to reach up to PL e (ISO 13849-1) or SIL cl 3 (IEC 62061)
Pack quantity: 1 pcs.
Connection: Cable: 2 m, PVC, Ø 5 mm; 4 x 0.25 mm²

Logistic parameters

ECCN:
Country of Origin: IT
EAN:
Weight: 0.19 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m